Environmental Specifications; Temperature; Humidity - Opticon NLV-3101-HD Specification Manual

Fixed position 2d imager scanner
Table of Contents

Advertisement

9. Environmental Specifications

9.1.

Temperature

Scanning performance is guaranteed when the range of ambient temperature around the scanner is
the following values:
Operating Temperature
Storage Temperature
<Conditions>
Bar Code Sample
Distance
Angle
Curvature
Scanning Test
* When you attach this scanner to a place with few crevices, or the bad place of breathability,
please check the circumference temperature of this scanner.
9.2.

Humidity

Scanning performance is guaranteed when the range of ambient humidity around the scanner is the
following values:
Operating Humidity
Storage Humidity
<Conditions>
Bar Code Sample
Distance
Angle
Curvature
: -20 ~ 50
°C
: -20 ~ 60
°C
: 0.33 mm UPC specified in Chapter 8.1
: 65 mm from the front edge of the scanner
: α = 0°, β =+15°, γ = 0°
: R = ∞
: Read at intervals of 300 ms
: 20 ~ 85% RH (no condensation, no frost)
: 20 ~ 90% RH (no condensation, no frost)
: 0.33 mm UPC specified in Chapter 8.1
: 65 mm from the front edge of the scanner
: α = 0°, β =+15°, γ = 0°
: R = ∞
25
NLV- 3101- HD
Specifications Manual