Aiming Pattern; Imaging Range - Opticon NLV-3101-HD Specification Manual

Fixed position 2d imager scanner
Table of Contents

Advertisement

7.2.

Aiming Pattern

The aiming is used for the following purpose:
1. Fill light to recognize the appropriate reading range.
2. Fill light when auto trigger is used.
The aiming specifications are as follows:
- An optical axis of imaging field of view and the center of horizontal aiming width coincide at a
distance of L=105±20 mm from the front edge of the scanner.
- The horizontal aiming width to the horizontal width of imaging filed of view at a distance of L=105 is
80%±10%.
7.3.

Imaging Range

The range is ±5% from the following values.
L: Distance from the front
edge of scanner
H: Horizontal imaging range
V: Vertical imaging range
The imaging range is no the scanning range but the imaging field of view.
Figure 13: Aiming Pattern and Imaging Range
[mm]
40
[mm]
30
[mm]
19
17
50
65
80
100
37
48
59
74
24
31
38
47
NLV- 3101- HD
Specifications Manual
120
89
56.4

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents