APPENDIX B
Table B–10: MODBUS MEMORY MAP (Sheet 53 of 61)
ADDR
REGISTER NAME
C470
Clear Platform Direct Input/Output Statistics Operand
C472
Reserved (13 items)
Platform Direct Outputs (Read/Write Setting) (32 modules)
C600
Direct Output 1 Operand
C602
Direct Output 1 Events
C603
...Repeated for Direct Output 2
C606
...Repeated for Direct Output 3
C609
...Repeated for Direct Output 4
C60C
...Repeated for Direct Output 5
C60F
...Repeated for Direct Output 6
C612
...Repeated for Direct Output 7
C615
...Repeated for Direct Output 8
C618
...Repeated for Direct Output 9
C61B
...Repeated for Direct Output 10
C61E
...Repeated for Direct Output 11
C621
...Repeated for Direct Output 12
C624
...Repeated for Direct Output 13
C627
...Repeated for Direct Output 14
C62A
...Repeated for Direct Output 15
C62D
...Repeated for Direct Output 16
C630
...Repeated for Direct Output 17
C633
...Repeated for Direct Output 18
C636
...Repeated for Direct Output 19
C639
...Repeated for Direct Output 20
C63C
...Repeated for Direct Output 21
C63F
...Repeated for Direct Output 22
C642
...Repeated for Direct Output 23
C645
...Repeated for Direct Output 24
C648
...Repeated for Direct Output 25
C64B
...Repeated for Direct Output 26
C64E
...Repeated for Direct Output 27
C651
...Repeated for Direct Output 28
C654
...Repeated for Direct Output 29
C657
...Repeated for Direct Output 30
C65A
...Repeated for Direct Output 31
C65D
...Repeated for Direct Output 32
Reset (Read/Write Setting)
C750
FlexLogic operand which initiates a reset
Control Pushbuttons (Read/Write Setting) (7 modules)
C760
Control Pushbutton 1 Function
C761
Control Pushbutton 1 Events
C762
...Repeated for Control Pushbutton 2
C764
...Repeated for Control Pushbutton 3
C766
...Repeated for Control Pushbutton 4
C768
...Repeated for Control Pushbutton 5
C76A
...Repeated for Control Pushbutton 6
C76C
...Repeated for Control Pushbutton 7
Force Contact Inputs/Outputs (Read/Write Settings)
C7A0
Force Contact Input x State (96 items)
C800
Force Contact Output x State (64 items)
Direct Inputs/Outputs (Read/Write Setting)
C880
Direct Device ID
C881
Direct I/O Channel 1 Ring Configuration Function
C882
Platform Direct I/O Data Rate
GE Multilin
RANGE
0 to 4294967295
---
0 to 4294967295
0 to 1
0 to 4294967295
0 to 1
0 to 1
0 to 2
0 to 3
1 to 16
0 to 1
64 to 128
F35 Multiple Feeder Protection System
B.4 MEMORY MAPPING
UNITS
STEP
FORMAT
---
1
F300
---
---
F001
---
1
F300
---
1
F102
---
1
F300
---
1
F102
---
1
F102
---
1
F144
---
1
F131
---
1
F001
---
1
F126
kbps
64
F001
DEFAULT
0
0
0
0 (Disabled)
B
0
0 (Disabled)
0 (Disabled)
0 (Disabled)
0 (Disabled)
1
0 (No)
64
B-61