APPENDIX B
Table B–10: MODBUS MEMORY MAP (Sheet 23 of 61)
ADDR
REGISTER NAME
4506
Auxiliary VT 1 Ratio
4508
...Repeated for VT Bank 2
4510
...Repeated for VT Bank 3
4518
...Repeated for VT Bank 4
4520
...Repeated for VT Bank 5
4528
...Repeated for VT Bank 6
Source Settings (Read/Write Setting) (6 modules)
4580
Source 1 Name
4583
Source 1 Phase CT
4584
Source 1 Ground CT
4585
Source 1 Phase VT
4586
Source 1 Auxiliary VT
4587
...Repeated for Source 2
458E
...Repeated for Source 3
4595
...Repeated for Source 4
459C
...Repeated for Source 5
45A3
...Repeated for Source 6
Power System (Read/Write Setting)
4600
Nominal Frequency
4601
Phase Rotation
4602
Frequency and Phase Reference
4603
Frequency Tracking Function
Incipient Cable Fault Detector (Read/Write Settings) (6 modules)
46B2
Incipient Cable Fault Detector 1 Function
46B3
Incipient Cable Fault Detector 1 Block
46B5
Incipient Cable Fault Detector 1 Source
46B6
Incipient Cable Fault Detector 1 Pickup
46B7
Incipient Cable Fault Detector 1 Mode
46B8
Incipient Cable Fault Detector 1 Trip Counts
46B9
Incipient Cable Fault Detector 1 Time Window
46BB
Incipient Cable Fault Detector 1 Reset Delay
46BC
Incipient Cable Fault Detector 1 Target
46BD
Incipient Cable Fault Detector 1 Events
46BE
...Repeated for Incipient Cable Fault Detector 2
46CA
...Repeated for Incipient Cable Fault Detector 3
46D6
...Repeated for Incipient Cable Fault Detector 4
46E2
...Repeated for Incipient Cable Fault Detector 5
46EE
...Repeated for Incipient Cable Fault Detector 6
Breaker Control (Read/Write Settings) (6 modules)
47D0
Breaker 1 Function
47D1
Breaker 1 Name
47D4
Breaker 1 Mode
47D5
Breaker 1 Open
47D7
Breaker 1 Close
47D9
Breaker 1 Phase A / Three-pole Closed
47DB
Breaker 1 Phase B Closed
47DD
Breaker 1 Phase C Closed
47DF
Breaker 1 External Alarm
47E1
Breaker 1 Alarm Delay
47E3
Breaker 1 Pushbutton Control
47E4
Breaker 1 Manual Close Recall Time
47E6
Breaker 1 Out of Service
47E8
Breaker 1 Block Open
GE Multilin
RANGE
1 to 24000
0 to 1
0 to 63
0 to 63
0 to 63
0 to 63
25 to 60
0 to 1
0 to 5
0 to 1
0 to 1
0 to 4294967295
0 to 5
0.1 to 10
0 to 1
1 to 10
0 to 1000
0 to 65.535
0 to 2
0 to 1
0 to 1
---
0 to 1
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 65.535
0 to 1
0 to 65.535
0 to 4294967295
0 to 4294967295
F35 Multiple Feeder Protection System
B.4 MEMORY MAPPING
UNITS
STEP
FORMAT
:1
1
F060
---
1
F206
---
1
F400
---
1
F400
---
1
F400
---
1
F400
Hz
1
F001
---
1
F106
---
1
F167
---
1
F102
---
1
F102
---
1
F300
---
1
F167
pu
0.01
F001
---
1
F254
---
1
F001
s
0.01
F003
s
0.001
F001
---
1
F109
---
1
F102
---
1
F102
---
---
F206
---
1
F157
---
1
F300
---
1
F300
---
1
F300
---
1
F300
---
1
F300
---
1
F300
s
0.001
F003
---
1
F102
s
0.001
F003
---
1
F300
---
1
F300
DEFAULT
1
"SRC 1"
0
0
0
B
0
60
0 (ABC)
0 (SRC 1)
1 (Enabled)
0 (Disabled)
0
0 (SRC 1)
50
0 (Number of
Counts)
2
1000
100
0 (Self-reset)
0 (Disabled)
0 (Disabled)
"Bkr 1"
0 (3-Pole)
0
0
0
0
0
0
0
0 (Disabled)
0
0
0
B-31