B.4 MEMORY MAPPING
Table B–10: MODBUS MEMORY MAP (Sheet 46 of 61)
ADDR
REGISTER NAME
B309
Wattmetric Ground Fault 1 Power Pickup Delay
B30A
Wattmetric Ground Fault 1 Curve
B30B
Wattmetric Ground Fault 1 Multiplier
B30C
Wattmetric Ground Fault 1 Block
B30E
Wattmetric Ground Fault 1 Target
B30F
Wattmetric Ground Fault 1 Events
B310
Wattmetric Ground Fault 1 Reference Power
B311
Wattmetric Ground Fault 1 Reserved
B312
...Repeated for Wattmetric Ground Fault 2
B324
...Repeated for Wattmetric Ground Fault 3
B
B336
...Repeated for Wattmetric Ground Fault 4
Wattmetric Ground Fault Actual Values (Read Only) (4 modules)
B360
Wattmetric Ground Fault 1 Operating Power
B362
...Repeated for Wattmetric Ground Fault 2
B364
...Repeated for Wattmetric Ground Fault 3
B366
...Repeated for Wattmetric Ground Fault 4
IEC 61850 XSWI Configuration (Read/Write Setting) (24 modules)
B370
FlexLogic Operand for IEC 61850 XSWI.ST.Loc Status
B373
...Repeated for module number 2
B376
...Repeated for module number 3
B379
...Repeated for module number 4
B37C
...Repeated for module number 5
B37F
...Repeated for module number 6
B382
...Repeated for module number 7
B385
...Repeated for module number 8
B388
...Repeated for module number 9
B38B
...Repeated for module number 10
B38E
...Repeated for module number 11
B391
...Repeated for module number 12
B394
...Repeated for module number 13
B397
...Repeated for module number 14
B39A
...Repeated for module number 15
B39D
...Repeated for module number 16
B3A0
...Repeated for module number 17
B3A3
...Repeated for module number 18
B3A6
...Repeated for module number 19
B3A9
...Repeated for module number 20
B3AC
...Repeated for module number 21
B3AF
...Repeated for module number 22
B3B2
...Repeated for module number 23
B3B5
...Repeated for module number 24
IEC 61850 XSWI Configuration (Read/Write Command) (24 modules)
B372
Command to Clear XSWI OpCnt (Operation Counter)
IEC 61850 GGIO1 Configuration Settings (Read/Write Setting)
B400
Number of Status Indications in GGIO1
B402
IEC 61850 GGIO1 Indication FlexLogic operands (128
items)
IEC 61850 Configurable GOOSE Transmission (Read/Write Setting) (8 modules)
B5A0
IEC 61850 Configurable GOOSE Function (GoEna)
B5A1
IEC 61850 Configurable GOOSE ID
B5C2
Configurable GOOSE Destination MAC Address
B5C5
IEC 61850 Configurable GOOSE VLAN Transmit Priority
B5C6
IEC 61850 Configurable GOOSE VLAN ID
B5C7
IEC 61850 Configurable GOOSE ETYPE APPID
B-54
RANGE
0 to 600
0 to 5
0.01 to 2
0 to 4294967295
0 to 2
0 to 1
0.001 to 1.2
0 to 1
0.000 to 999999.999
0 to 4294967295
0 to 1
8 to 128
0 to 4294967295
0 to 1
---
---
0 to 7
0 to 4095
0 to 16383
F35 Multiple Feeder Protection System
APPENDIX B
UNITS
STEP
FORMAT
s
0.01
F001
---
1
F236
0 (Definite Time)
s
0.01
F001
---
1
F300
---
1
F109
---
1
F102
pu
0.001
F001
---
1
F001
W
0.001
F060
---
1
F300
---
1
F126
---
8
F001
---
1
F300
---
1
F102
---
---
F209
"GOOSEOut_x_"
---
---
F072
---
1
F001
---
1
F001
---
1
F001
DEFAULT
20
100
0
0 (Self-reset)
0 (Disabled)
500
0
0
0
0 (No)
8
0
1 (Enabled)
0
4
0
0