GE UR F35 Series Instruction Manual page 501

Multiple feeder protection system
Hide thumbs Also See for UR F35 Series:
Table of Contents

Advertisement

APPENDIX B
Table B–10: MODBUS MEMORY MAP (Sheet 55 of 61)
ADDR
REGISTER NAME
CAE2
Direct Input/Output Ch 1 Unreturned Messages Alarm
Threshold
CAE3
Direct Input/Output Ch 1 Unreturned Messages Alarm
Events
CAE4
Reserved (4 items)
CAE8
Direct Input/Output Ch 2 Unreturned Messages Alarm
Function
CAE9
Direct Input/Output Ch 2 Unreturned Messages Alarm Msg
Count
CAEA
Direct Input/Output Ch 2 Unreturned Messages Alarm
Threshold
CAEB
Direct Input/Output Channel 2 Unreturned Messages Alarm
Events
CAEC
Reserved (4 items)
Remote Devices (Read/Write Setting) (16 modules)
CB00
Remote Device 1 GSSE/GOOSE Application ID (GOID)
CB21
Remote Device 1 GOOSE Ethernet APPID
CB22
Remote Device 1 GOOSE Dataset
CB23
Remote Device 1 in PMU Scheme
CB24
Reserved
CB25
...Repeated for Device 2
CB4A
...Repeated for Device 3
CB6F
...Repeated for Device 4
CB94
...Repeated for Device 5
CBB9
...Repeated for Device 6
CBDE
...Repeated for Device 7
CC03
...Repeated for Device 8
CC28
...Repeated for Device 9
CC4D
...Repeated for Device 10
CC72
...Repeated for Device 11
CC97
...Repeated for Device 12
CCBC
...Repeated for Device 13
CCE1
...Repeated for Device 14
CD06
...Repeated for Device 15
CD2B
...Repeated for Device 16
Remote Inputs (Read/Write Setting) (32 modules)
CFA0
Remote Input 1 Device
CFA1
Remote Input 1 Bit Pair
CFA2
Remote Input 1 Default State
CFA3
Remote Input 1 Events
CFA4
Remote Input 1 Name
CFAA
...Repeated for Remote Input 2
CFB4
...Repeated for Remote Input 3
CFBE
...Repeated for Remote Input 4
CFC8
...Repeated for Remote Input 5
CFD2
...Repeated for Remote Input 6
CFDC
...Repeated for Remote Input 7
CFE6
...Repeated for Remote Input 8
CFF0
...Repeated for Remote Input 9
CFFA
...Repeated for Remote Input 10
D004
...Repeated for Remote Input 11
D00E
...Repeated for Remote Input 12
D018
...Repeated for Remote Input 13
D022
...Repeated for Remote Input 14
D02C
...Repeated for Remote Input 15
GE Multilin
RANGE
1 to 1000
0 to 1
1 to 1000
0 to 1
100 to 10000
1 to 1000
0 to 1
1 to 1000
---
0 to 16383
0 to 16
0 to 1
0 to 3
1 to 32
0 to 96
0 to 3
0 to 1
1 to 64
F35 Multiple Feeder Protection System
B.4 MEMORY MAPPING
UNITS
STEP
FORMAT
---
1
F001
---
1
F102
---
1
F001
---
1
F102
---
1
F001
---
1
F001
---
1
F102
---
1
F001
---
---
F209
"Remote Device
---
1
F001
---
1
F184
---
1
F126
---
1
F626
---
1
F001
---
1
F156
---
1
F086
---
1
F102
---
1
F205
DEFAULT
10
0 (Disabled)
10
0 (Disabled)
600
10
0 (Disabled)
B
10
1"
0
0 (Fixed)
0 (No)
0 (None)
1
0 (None)
0 (Off)
0 (Disabled)
"Rem Ip 1"
B-63

Advertisement

Table of Contents
loading

Table of Contents