Technogym WAVE EXCITE+ Service Maintenance Manual page 87

Hide thumbs Also See for WAVE EXCITE+:
Table of Contents

Advertisement

Cardio WAVE EXCITE +: Service & maintenance manual - rev. 4.1
Replace the connectoring
cables between the High
Kit and Low Kit.
THERE IS NO
HR SIGNAL
(Hand Sendor)
Check if using a chest belt
that you are sure it's ok, it works
properly.
The problem persists?
Check if the +5Vdc are at the
input of Receiver Board.
Are them present?
YES
Check if the +5Vdc are at the
output of the ARM/CPU Board.
Are them present?
ARM/CPU Board
defective.
Replace.
YES
A
NO
1
YES
NO
2
NO
Continued on following page ...
OK
NO
3
Check if the SW and the
gruonding of Receiver Board.
The problem persist?
YES
Receiver Board
defective.
Replace.
Pagina 6.29