Technogym WAVE EXCITE+ Service Maintenance Manual page 85

Hide thumbs Also See for WAVE EXCITE+:
Table of Contents

Advertisement

Cardio WAVE EXCITE +: Service & maintenance manual - rev. 4.1
Follow the procedure step by step to correctly diagnose the problem. Take particular care with the
checks highlighted by circled numbers, which are described in detail below:
(1)
In Place the tester probes across pins 1 and 3 of connector CN1 of the TGS reader. The
measured value should be +12Vdc.
(2)
As for step (1) but across pins 1 and 8 of connector CN19 (CPU Board) or on the CN7
connector (ARM Board).
(3)
Use the serial communications test described at paragraph: 6.1.3.3 "Serial Ports Test".
If you replace ARM/CPU Board, check that its SW version is updated, otherwise install
the last version.
Pagina 6.27