EXCITE LIVE (DF*) Pre-Installation Requirements Rev. 2.0 Table of contents GENERAL WARNINGS ..................7 NETWORK DESIGN – CONFIGURATION AND INSTALLATION ......9 NETWORK DESIGN AND INSTALLATION ..............9 CONFIGURATION AND INSTALLATION ..............9 DISPLAY ......................11 RUN LIVE ........................11 BIKE LIVE ........................12 RECLINE LIVE ......................13 SYNCHRO LIVE ......................14 SYNCHRO AR LIVE (Adjustable ramp) ...............14 CLIMB LIVE .........................15...
Page 4
EXCITE LIVE (DF*) Pre-Installation Requirements Rev. 2.0 6.3.3 ADDITIONAL REQUIREMENTS ................37 WIRELESS GUIDELINES ...................37 MAXIMUM NUMBER OF EQUIPMENT CONNECTED TO ONE ACCESS POINT ..38 INTERNET CONNECTION BANDWIDTH REQUIREMENTS (ONLY FOR LIVE 16/LIVE 19 UI) ...........................38 INTERNET CONNECTION BANDWIDTH REQUIREMENTS (ONLY FOR LIVE 10 UI) . FIREWALL / ROUTER RULES FOR ACCESS TO MYWELLNESS CLOUD SERVIC- ES ..........................41 PROXY (only for LIVE 16/LIVE 19 UI) .................42...
Page 5
This document contains proprietary information that is covered by copyright. Allrights re- served. No part of this document may be circulated, copied, reproduced or translated into another language without the prior written consent of Technogym. Additional information may be included in the After Sales technical documents, available in the official ‘After Sales documents repository’.
Page 6
EXCITE LIVE (DF*) Pre-Installation Requirements Rev. 2.0 Blank page - 6 - Document uncontrolled when printed...
EXCITE LIVE (DF*) Pre-Installation Requirements Rev. 2.0 GENERAL WARNINGS This manual includes informative notes with specific meanings: Safety signs classified according to the relative seriousness of the potential hazards: DANGER: Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury. This signal word is to be limited to the most extreme situations.
Page 8
EXCITE LIVE (DF*) Pre-Installation Requirements Rev. 2.0 Blank page - 8 - Document uncontrolled when printed...
INSTALLATION 2.1 NETWORK DESIGN AND INSTALLATION During the network design and preparation phases, Technogym requests to be put in touch with the technicians of the company performing the work, in order to obtain and provide technical infor- mation, so that the network is installed and configured according to the required technical require- ments.
Page 10
EXCITE LIVE (DF*) Pre-Installation Requirements Rev. 2.0 Blank page - 10 - Document uncontrolled when printed...
EXCITE LIVE (DF*) Pre-Installation Requirements Rev. 2.0 DISPLAY The cardio equipment of the EXCITE LIVE may be fitted with LIVE 16/LIVE 19 display (depending on the type of machine) and/or with LIVE 10 display. For details, see the following paragraphs. 3.1 RUN LIVE The RUN LIVE (DFK*) is fitted with LIVE 10 and LIVE 19 display.
EXCITE LIVE (DF*) Pre-Installation Requirements Rev. 2.0 3.2 BIKE LIVE The BIKE LIVE (DFC*) is fitted with LIVE 10 and LIVE 16 display. Fig. 3- LIVE 16 DISPLAY Fig. 4- LIVE 10 DISPLAY - 12 - Document uncontrolled when printed...
EXCITE LIVE (DF*) Pre-Installation Requirements Rev. 2.0 3.3 RECLINE LIVE The RECLINE LIVE (DFD*) is fitted with LIVE 10 and LIVE 16 display. Fig. 5- LIVE 16 DISPLAY Fig. 6- LIVE 10 DISPLAY Document uncontrolled when printed - 13 -...
EXCITE LIVE (DF*) Pre-Installation Requirements Rev. 2.0 3.4 SYNCHRO LIVE The SYNCHRO LIVE (DF5*) is fitted only with LIVE 10 display. Fig. 7- LIVE 10 DISPLAY 3.5 SYNCHRO AR LIVE (Adjustable ramp) The SYNCHRO AR LIVE (DFH*) is fitted with LIVE 10 and LIVE 16 display. Fig.
EXCITE LIVE (DF*) Pre-Installation Requirements Rev. 2.0 Fig. 9- LIVE 10 DISPLAY 3.6 CLIMB LIVE The CLIMB LIVE (DFE*) is fitted with LIVE 10 and LIVE 16 display. Fig. 10- LIVE 16 DISPLAY Document uncontrolled when printed - 15 -...
EXCITE LIVE (DF*) Pre-Installation Requirements Rev. 2.0 Fig. 11- LIVE 10 DISPLAY 3.7 VARIO LIVE The VARIO LIVE (DFF*) is fitted with LIVE 10 and LIVE 16 display. Fig. 12- LIVE 16 DISPLAY - 16 - Document uncontrolled when printed...
EXCITE LIVE (DF*) Pre-Installation Requirements Rev. 2.0 Fig. 13- LIVE 10 DISPLAY 3.8 TOP LIVE The TOP LIVE (DF7*) is fitted with LIVE 10 and LIVE 16 display. Fig. 14- LIVE 16 DISPLAY Document uncontrolled when printed - 17 -...
Page 18
EXCITE LIVE (DF*) Pre-Installation Requirements Rev. 2.0 Fig. 15- LIVE 10 DISPLAY - 18 - Document uncontrolled when printed...
EXCITE LIVE (DF*) Pre-Installation Requirements Rev. 2.0 ELECTRICAL AND TECHNICAL DATA/ REQUIREMENTS 4.1 DATA & REQUIREMENTS 4.1.1 Run Live Technical Data DFKGA (RUN LIVE 10) DFKUA (RUN LIVE 19) 100÷240 Vac 50/60 Hz Power supply Max Absorption 20A @ 110 Vac, 50/60 Hz 16A @ 230 Vac, 50/60 Hz (theoretical value) 160 kg (353 lb)
EXCITE LIVE (DF*) Pre-Installation Requirements Rev. 2.0 We recommend a dedicated power supply line for each machine. 4.1.2 Bike Live Technical Data Mains Powered version Human-Powered version (DFC*3) (DFC*4) 100÷240 Vac 50/60 Hz Power supply Max Absorption 1A @ 110 Vac, 50/60 Hz 1A @230 Vac, 50/60 Hz (theoretical value) 160 VA...
EXCITE LIVE (DF*) Pre-Installation Requirements Rev. 2.0 Technical Data Mains Powered version Human-Powered version (DFD*3) (DFD*4) 2 kg (4 lb) Maximum capacity of water bottle holder IP20 Protection rating Electric isolation class Class I Tab. 3 4.1.4 Synchro Live Technical Data- SYNCHRO LIVE (DF5*) Mains Powered version Human-Powered version (DF5G3A)
EXCITE LIVE (DF*) Pre-Installation Requirements Rev. 2.0 Technical Data- SYNCHRO AR LIVE (DFH*) Mains Powered version (DFH*3Q) - (DFH*3A) 2x3,15A (F) Fuses Braking power (90 spm) 45÷493 W SYNCHRO AR LIVE 10: 170 kg (375 lb) Weight of equipment SYNCHRO AR LIVE 16: 172 kg (379 lb) 180 kg (397 lb) Maximum user weight 2 kg (4 lb)
EXCITE LIVE (DF*) Pre-Installation Requirements Rev. 2.0 4.1.7 Vario Live Technical Data Mains Powered version Human-Powered version (DFF*3) (DFF*4) 100÷240 Vac 50/60 Hz Power supply 1A @ 110 Vac, 50/60 Hz Max Absorption (theoretical value) 1A @230 Vac, 50/60 Hz 160 VA Maximum input power Fuses...
EXCITE LIVE (DF*) Pre-Installation Requirements Rev. 2.0 Technical Data Mains Powered version (DF7*3) 2 kg (4 lb) Maximum capacity of water bot- tle holder 180 kg (397 lb) Maximum user weight Weight of the seat 25,8 kg (57 lb) IP20 Protection rating Electric isolation class Class I...
Page 25
EXCITE LIVE (DF*) Pre-Installation Requirements Rev. 2.0 _A free space - at least 60 cm wide - around the other products (BIKE, SYNCHRO, RECLINE, CLIMB, VARIO, TOP) as shown below : Fig. 17 Fig. 18 Document uncontrolled when printed - 25 -...
Page 26
EXCITE LIVE (DF*) Pre-Installation Requirements Rev. 2.0 Fig. 19 Fig. 20 - 26 - Document uncontrolled when printed...
Page 27
EXCITE LIVE (DF*) Pre-Installation Requirements Rev. 2.0 Fig. 21 Fig. 22 Document uncontrolled when printed - 27 -...
Page 28
EXCITE LIVE (DF*) Pre-Installation Requirements Rev. 2.0 Blank page - 28 - Document uncontrolled when printed...
EXCITE LIVE (DF*) Pre-Installation Requirements Rev. 2.0 ELECTRICAL CONNECTION (mains powered machines) 5.1 INTRODUCTION Before connecting the product to the mains power supply, ensure that the electrical system speci- fications comply with current regulations. Check the mains power supply specifications on the identification label.
EXCITE LIVE (DF*) Pre-Installation Requirements Rev. 2.0 5.2 POSITIONING OF POWER INLET Fig. 23 - RUN LIVE Fig. 24- BIKE LIVE - 30 - Document uncontrolled when printed...
Page 31
EXCITE LIVE (DF*) Pre-Installation Requirements Rev. 2.0 Fig. 25 - RECLINE LIVE Document uncontrolled when printed - 31 -...
Page 32
EXCITE LIVE (DF*) Pre-Installation Requirements Rev. 2.0 Fig. 26 - SYNCHRO LIVE Fig. 27 - CLIMB LIVE - 32 - Document uncontrolled when printed...
Page 33
EXCITE LIVE (DF*) Pre-Installation Requirements Rev. 2.0 Fig. 28 - VARIO LIVE Document uncontrolled when printed - 33 -...
Page 34
EXCITE LIVE (DF*) Pre-Installation Requirements Rev. 2.0 Fig. 29 - TOP LIVE - 34 - Document uncontrolled when printed...
The equipment fitted with LIVE 10 UI support a wireless internet connection. In all cases, the network must be installed and configured by the customer before Technogym de- livers the product, in accordance with the technical specifications set out below.
EXCITE LIVE (DF*) Pre-Installation Requirements Rev. 2.0 fixed IPs address _ There must be only one dedicated Access Point / Wi-Fi router that provides the service; _ DHCP enabled; _ It’s recommended to avoid broadcasting the same SSID, through 2.4 and 5 GHz, at the same time.
EXCITE LIVE (DF*) Pre-Installation Requirements Rev. 2.0 6.5 MAXIMUM NUMBER OF EQUIPMENT CONNECTED TO ONE ACCESS POINT _Up to 5 devices: use a commercial Access Point. _More than 5 devices: use a professional Access Point (see the technical datasheet). For more details about Access Point, refer to the AP technical specifications. 6.6 INTERNET CONNECTION BANDWIDTH REQUIREMENTS (ONLY FOR LIVE 16/LIVE 19 UI) The below table illustrates the minimum infrastructure requirements, based on the number of equip-...
Page 39
EXCITE LIVE (DF*) Pre-Installation Requirements Rev. 2.0 Fig. 30 Document uncontrolled when printed - 39 -...
EXCITE LIVE (DF*) Pre-Installation Requirements Rev. 2.0 6.7 INTERNET CONNECTION BANDWIDTH REQUIREMENTS (ONLY FOR LIVE 10 UI) The below table illustrates the minimum infrastructure requirements, based on the number of equip- ment fitted with LIVE 10 UI. In detail, the requirements (minimum and target) are based on average usage of equipment fitted with LIVE 10 UI at the same time.
Free access to the Internet must be guaranteed for correct use of the Mywellness Cloud services, and in particular access to the following DNS names must never be disabled. DNS Names for LIVE 16/LIVE 19 UI mywellness.com technogym.com facebook.com facebook.net fbcdn.net google.com...
EXCITE LIVE (DF*) Pre-Installation Requirements Rev. 2.0 6.9 PROXY (only for LIVE 16/LIVE 19 UI) PROXY not supported. - 42 - Document uncontrolled when printed...
EXCITE LIVE (DF*) Pre-Installation Requirements Rev. 2.0 STANDARD TV TECHNICAL SPECIFICATIONS (ONLY FOR LIVE 16/LIVE 19 UI) 7.1 INTRODUCTION The data useful to antenna installers for checking the suitability of the antenna signal input to the equipment with LIVE 16/LIVE 19 UI are detailed below. The readings in the tables below must be taken directly at the antenna input connector on the equipment.
EXCITE LIVE (DF*) Pre-Installation Requirements Rev. 2.0 Fig. 32 (*): DTMB -> UPGRADE KIT A0001108. 7.2 VIRTUAL LAN LIVE 16/LIVE 19 UI doesn’t manage the VLANs because it has only one CPU port that manages both Internet and IPTV on the same network.Therefore it’s not possible to set a VLAN network on IPTV infrastructure.
EXCITE LIVE (DF*) Pre-Installation Requirements Rev. 2.0 7.4 LIVE 16/LIVE 19 UI: DVB-T / T2 / C / ISDB-Tb VERSION (-T) STANDARD OPTIONS NOT ENCRYPTED ▪ Analog TV + FM Radio; ▪ Digital TV DVB-T/ DVB-T2 (mpeg2, H264, HEVC) not encrypted; ▪...
Page 46
EXCITE LIVE (DF*) Pre-Installation Requirements Rev. 2.0 INTERNET IPTV (e.g. Netflix) ANDROID APP (FREE) – Compatibility check SUPPORTED ANALOGIC STANDARDS (DVB-T/T2/C VERSION) ▪ PAL B/G , PAL I , SECAM DK , SECAM L , SECAM L1; ▪ NTSC M , PAL M , PAL N; ▪...
Page 47
EXCITE LIVE (DF*) Pre-Installation Requirements Rev. 2.0 COAX QAM Pro:IDIOM®: ATSC/ QAM-B Pro:IDIOM® LIVE 16/LIVE 19 UI VERSION “-T“ + UPGRADE KIT A0000845 CABLE TV: QAM-B (64/256 QAM –ITU J83 Annex B) – Channel spa- cing 6 MHz DIGITAL TV : ATSC (free to air) ANALOG TV: Not available Broadcast System RADIO FM: Not available...
EXCITE LIVE (DF*) Pre-Installation Requirements Rev. 2.0 7.5 LIVE 16/LIVE 19 UI - VERSION (-A) STANDARD OPTIONS - USA/CANADA NOT ENCRYPTED ▪ Analog TV (e.g. NTSC) + FM Radio; ▪ Digital TV (coax ATSC) not encrypted; ▪ Cable TV (coax QAM-B 64/256) not encrypted; ▪...
Page 49
EXCITE LIVE (DF*) Pre-Installation Requirements Rev. 2.0 STANDARD (NOT ENCRYPTED) ATSC/ QAM-B / ANALOG NTSC / IPTV LIVE 16/LIVE 19 UI VERSION “-A“ Broadcast System CABLE TV: QAM-B (64/256 QAM –ITU J83 Annex B) – Channel spa- cing 6 MHz DIGITAL TV : ATSC (free to air) ANALOG TV: YES RADIO FM: YES...
Page 50
EXCITE LIVE (DF*) Pre-Installation Requirements Rev. 2.0 COAX QAM Pro:IDIOM®: ATSC/ QAM-B Pro:IDIOM® LIVE 16/LIVE 19 UI VERSION “-A“ + UPGRADE KIT A0000845 Broadcast System CABLE TV: QAM-B (64/256 QAM –ITU J83 Annex B) – Channel spa- cing 6 MHz DIGITAL TV : ATSC (free to air) ANALOG TV: Not available RADIO FM: Not available...
EXCITE LIVE (DF*) Pre-Installation Requirements Rev. 2.0 7.6 LIVE 16/LIVE 19 UI: DTMB DIGITAL DTMB DIGITAL UPGRADE KIT A0001108 Broadcast System DIGITAL TV : DTMB ANALOG TV: NOT SUPPORTED ANALOG RADIO FM: NOT SUPPORTED RF INPUT: F-Type connector INPUT INPEDENCE: 75 Ohm (max nondestructive input power: 10 dBm) Signal level DTMB...
Page 52
EXCITE LIVE (DF*) Pre-Installation Requirements Rev. 2.0 Blank page. - 52 - Document uncontrolled when printed...
EXCITE LIVE (DF*) Pre-Installation Requirements Rev. 2.0 LIST OF CHANGES FOR MANUAL REVISION The main changes made to this manual, are listed below in chronological order. 9.1 REVISION 1.0 First released version. 9.2 REVISION 2.0 New §4.2 PLACE OF USAGE Modified §6.3 WI-FI NETWORK REQUIREMENTS: updated the wi-fi network requirements for LIVE 16/LIVE 19 Modified §7.4 LIVE 16/LIVE 19 UI: DVB-T / T2 / C / ISDB-Tb VERSION (-T) STANDARD OP-...
Page 56
EXCITE LIVE (DF*) Pre-Installation Requirements Rev. 2.0 Blank page - 56 - Document uncontrolled when printed...