Technogym WAVE EXCITE+ Service Maintenance Manual page 69

Hide thumbs Also See for WAVE EXCITE+:
Table of Contents

Advertisement

Cardio WAVE EXCITE +: Service & maintenance manual - rev. 4.1
Follow the procedure step by step to correctly diagnose the problem. Take particular care with the
checks highlighted by circled numbers, which are described in detail below:
(1)
Check if the fuse on the ELT-01 cable is whole. If necessary replace the F5A fuse (A)
indicated in the figure follows.
(2)
Clean the contacts of fuse holder inside of the fuse housing, highlight in the figure follows:
At the end, to check if the contacts inside of the fuse housing are intact and functioning,
check the continuity of red cable (V+ battery). Carry out the measure on the CN3
connector of Brake Board and on the faston connector of battery. The result should be
0Ω (ohm).
Figure 6.3-1
Figure 6.3-2
Pagina 6.11

Advertisement

Table of Contents
loading

Table of Contents