Figure 9: Tube Puller Insertion - Thermal Solutions Arctic Installation & Operation Manual

Table of Contents

Advertisement

3. Loosen tube-ends. Insert tube puller between the tube-end and header. Apply pressure to the
Arctic Installation and Operation Manual
puller and strike the side of the tube two or three times with a hammer to help loosen the tube-
end in the upper and lower header.
4. Pull lower tube end. Wedge the tube puller under the flange of the tube. Drive the tube puller
with several blows with a hammer on the end of the handle. Alternate with downward blows to
lift tube-end.
5. Clear tube-end from the header. Continue driving wedge under and leveraging flange up until it
pops the end of the tube free from the hole in the header.
Pull upper tube-end. Repeat the procedure to the pull the tube-end of the same tube from the
upper header.
6.
Prepare the headers and replacement tubes. Before placing a new tube into the header, clean
the holes by wiping gently with emery cloth to be sure that there are no burrs. Clean the
7.
replacement tube-ends of any rust or debris. With a small brush, apply a thin coating of gray
pipe dope around the inside of the hole. Pipe dope may also be applied to the tube-end. Cutting
oil may be mixed with the pipe dope for easier application.
Thermal Solutions, 1175 Manheim Pike, Lancaster, PA 17601 Web:
Phone: 717-239-7642 Fax: 877-501-5212 Email:
36

Figure 9: Tube Puller Insertion

Form: 2435
Revision: 8
Date: 9-19-2016
www.thermalsolutions.com
sales@thermalsolutions.com