Item
Designation
(13)
Welding current indicator
to indicate the welding current for the parameters
-
Starting current I
-
Welding current I
-
Reduced current I
-
End current I
E
Before welding commences, the left-hand digital display shows the set value. For
I
, I
and I
, the right-hand digital display also shows the respective percentage
S
2
E
of the welding current I
After the start of welding, the welding parameter I
left-hand digital display shows the actual welding current value.
In the welding parameters overview (11), LEDs for the various parameters (I
etc.) light up to show the current position in the welding process.
(14)
Left Parameter Selection button
for selecting welding parameters within the welding parameters overview (11)
When a welding parameter is selected, the LED on the relevant parameter sym-
bol lights up.
S
1
2
.
1
is automatically selected. The
1
, t
,
S
up
31