SECTION 4 - MACHINE OPERATION
4.3

MOTOR OPERATION

Power/Emergency Stop Switch

This red, mushroom-shaped switch provides battery power to the
Platform/Ground Select switch, when pulled out (on), for all
machine functions. The switch should be pushed in (off ) when
recharging the batteries or parking the machine overnight.

Platform/Ground Select Switch

The Platform/Ground Select switch functions to direct battery
power to the desired control station when the POWER/EMER-
GENCY STOP switch is pulled out (on). With the switch in the
GROUND position, battery power is supplied to the ground con-
trol station. When the switch is in the PLATFORM position, battery
power is supplied to the platform control station.
The key is removable in the platform position on CE machines.
The key must be available to ground personnel in the event of an
emergency.
4-6

Motor Activation

FOOTSWITCH MUST BE DEPRESSED PRIOR TO ACTIVATING ANY FUNCTION, OTHER-
WISE FUNCTION WILL NOT OPERATE.
The motor becomes activated and operates the desired function
when the Emergency Stop switch is pulled out (on), the Platform/
Ground select switch is in the appropriate position and the Foot-
switch is depressed.
IF A MOTOR MALFUNCTION NECESSITATES UNSCHEDULED SHUTDOWN, DETERMINE
AND CORRECT THE CAUSE BEFORE RESUMING ANY OPERATION.
ALWAYS POSITION EMERGENCY STOP SWITCH TO THE 'OFF' POSITION (PUSHED IN)
WHEN MACHINE IS NOT IN USE.
– JLG Lift –
3121252