Anritsu S412E Maintenance Manual page 51

Lmr master vector network/spectrum analyzer
Hide thumbs Also See for S412E:
Table of Contents

Advertisement

Chapter 5 — Option Verification
Procedure
1. Connect the MA2482D Power Sensor to the power meter and zero the sensor.
2. Set the cal factor frequency of the power sensor to 2600.5 MHz.
3. Connect the equipment as shown in
4. Set the MG3700A as follows:
a. Press the yellow Preset key (answer yes to the question).
b. Press the Set key.
c. Press the (F1) soft key to select Load File to Memory.
d. Press the (F1) soft key again to select Select Package.
e. Using the Down Arrow key step through the selection list until WiMax is highlighted.
f. Press the Set key.
g. Press the Return (F6) soft key.
h. Press the Set key. The Select Package list box will appear. Again select WiMax and the Set key.
i. Another file list will appear. Select (highlight) Mx10g32.
j. Press the Set key.
k. Press the MOD On/Off key and verify that the LED is on. Confirm that the "Playing" indicator is
displaying the moving pattern.
l. Press the Frequency key, then enter 2600.5 MHz.
m. Press the Level key, then enter 2 dBm. Turn the output On.
5. Adjust the MG3700A level setting with the knob so that the power meter reads –15.0 dBm ± 0.2 dB.
6. Set the S412E to Fixed WiMax Signal Analyzer mode and preset the unit.
7. Set the S412E as follows:
a. Press the Freq main menu key and set the center frequency to 2600.5 MHz.
b. Press the Setup submenu key and set the Bandwidth to 10 MHz.
c. Press the CP Ratio submenu key (under the Setup submenu key) and set the CP Ratio to 1/32.
d. Press the Measurements submenu key and select RF, then select Power vs. Time.
8. Record the S412E Channel Power (RSSI) reading in the Measured Channel Power (RSSI) column of
Table A-18, "Option 46, Fixed WiMAX Channel Power
9. Calculate the Channel Power Error by subtracting the S412E Channel Power (RSSI) reading from the
power meter reading in
10. Verify that the error is within specification.
11. Adjust the MG3700A level setting to approximately –33 dBm so that the power meter reads –50.0 dBm.
12. Record the S412E Channel Power (RSSI) reading in the Measured Channel Power (RSSI) column of
Table
A-18.
13. Calculate the Channel Power Error by subtracting the S412E Channel Power (RSSI) reading from the
power meter reading in
14. Verify that the error is within specification.
15. Set the cal factor frequency of the power sensor to 3600.5 MHz.
16. Set the MG3700A frequency to 3600.5 MHz.
17. Change the S412E center frequency to 3600.5 MHz.
18. Measure the Channel Power (RSSI) for both –15 and –50 dBm and then record the measured result and
calculated error in
S412E MM
5-4 Fixed WiMAX Signal Analyzer Verification, Option 46 and 47
Figure
Step
5. Record the result in the Error column of
Step
11. Record the result to the Error column of
Table
A-18.
PN: 10580-00324 Rev. N
5-1.
Accuracy.
Table
A-18.
Table
A-18.
5-7

Advertisement