Anritsu SM/PL Series Calibration Manual
Anritsu SM/PL Series Calibration Manual

Anritsu SM/PL Series Calibration Manual

Precision loads

Advertisement

Quick Links

A l l t e s t I n s t r u me n t s , I n c .
5 0 0 C e n t r a l A v e .
F a r mi n g d a l e , N J 0 7 7 2 7
P : ( 7 3 2 ) 9 1 9 - 3 3 3 9
F : ( 7 3 2 ) 9 1 9 - 3 3 3 2
a l l t e s t . n e t
s s a l e s @ a l l t e s t . n e t
T h e t e s t & me a s u r e me n t
e q u i p me n t y o u n e e d a t
t h e p r i c e y o u w a n t .
A l l t e s t c a r r i e s t h e w o r l d ' s l a r g e s t s e l e c t i o n o f
u s e d / r e f u r b i s h e d b e n c h t o p t e s t & me a s u r e me n t
e q u i p me n t a t 5 0 % t h e p r i c e o f n e w .
O O u r e q u i p me n t i s g u a r a n t e e d w o r k i n g , w a r r a n t i e d , a n d
a v a i l a b l e w i t h c e r t i f i e d c a l i b r a t i o n f r o m o u r i n - h o u s e s t a f f
o f t e c h n i c i a n s a n d e n g i n e e r s .
• 1 0 + f u l l t i me t e c h n i c i a n s w i t h o v e r 1 5 0 y e a r s o f
s p e c i a l i z a t i o n
• 9 0 d a y w a r r a n t y & 5 d a y r i g h t o f r e t u r n o n a l l
e q u i p me n t
• • 1 - 3 y e a r w a r r a n t i e s f o r n e w a n d
p r e mi u m- r e f u r b i s h e d e q u i p me n t
• E v e r y u n i t t e s t e d t o O E M s p e c i f i c a t i o n s
• S a t i s f a c t i o n g u a r a n t e e d
Y o u h a v e p l a n s , w e w i l l h e l p y o u a c h i e v e t h e m.
A n y p r o j e c t . A n y b u d g e t .
t
G e t a q u o t e t o d a y !
C C a l l ( 7 3 2 ) 9 1 9 - 3 3 3 9 o r e ma i l s a l e s @a l l t e s t . n e t .

Advertisement

Table of Contents
loading

Summary of Contents for Anritsu SM/PL Series

  • Page 1 T h e t e s t & me a s u r e me n t e q u i p me n t y o u n e e d a t t h e p r i c e y o u w a n t . A l l t e s t I n s t r u me n t s , I n c .
  • Page 2 Calibration Guide Model SM/PL Series Precision Loads Anritsu Company Part Number: 10100-00056 490 Jarvis Drive Revision: B Morgan Hill, CA 95037-2809 Published: January 2010 Copyright 2009-2010 Anritsu Company...
  • Page 4 Anritsu Company. UPDATES Updates, if any, can be downloaded from the Documents area of the Anritsu web site at: http://www.us.anritsu.com For the latest service and sales information in your area, please visit:...
  • Page 5 Before you export this product or any of its manuals, please contact Anritsu Company to confirm whether or not these items are export-controlled. When disposing of export-controlled items, the products and manuals need to be broken or shredded to such a degree that they cannot be unlawfully used for military purposes.
  • Page 6 Safety Symbols To prevent the risk of personal injury or loss related to equipment malfunction, Anritsu Company uses the following symbols to indicate safety-related information. For your own safety, please read the information carefully before operating the equipment. Symbols Used in Manuals...
  • Page 7 Some or all of the following five symbols may or may not be used on all Anritsu equipment. In addition, there may be other labels attached to products that are not shown in the diagrams in this manual.
  • Page 8: Table Of Contents

    Return Loss Verification Procedure ... . 2-4 DC Resistance Verification Procedure..2-4 Model SM/PL Series CG PN: 10100-00056 Rev. B Contents-1...
  • Page 9 Contents-2 PN: 10100-00056 Rev. B Model SM/PL Series CG...
  • Page 10: Chapter 1-General Information

    Chapter 1 — General Information Introduction This guide provides performance verification procedures for Anritsu Model SM/PL, SM/PLNF, SM/PL-1 and SM/PLNF-1 Precision Loads. Description The SM/PL Series consists of the following models: Table 1-1. SM/PL Series Precision Loads Anritsu Part Number...
  • Page 11: Recommended Test Equipment

    Anritsu Model SC6650 (Sliding Loads included) Connector Type: Adapter Anritsu Model 34NKF50 K female to N male Connector Type: Adapter Anritsu Model 34NFKF50 K female to N female Digital Agilent Model 34401A Multi-meter PN: 10100-00056 Rev. B Model SM/PL Series CG...
  • Page 12: Chapter 2-Performance Verification

    SM/PL, SMPLNF, SM/PL-1 and SM/PLNF-1 Precision Loads. The tests include: • Return Loss Verification • Precision Load DC Resistance Test Specifications Refer to Table 2-1 for the SM/PL series specifications. Table 2-1. SM/PL Series Specifications Anritsu Part Number SM/PL SM/PL-1 Specification...
  • Page 13: Verification Procedures

    “Return Loss Verification Procedure” on page 2-4 • “DC Resistance Verification Procedure” on page 2-4 Equipment Required • Anritsu Model 37247D or 37347D Vector Network Analyzer • Anritsu Model SC6650 N Connector Calibration Kit • Anritsu Model 34NKF50 or 34NFKF50 Adapter PN: 10100-00056 Rev. B...
  • Page 14: Vna Calibration Procedure

    N (F) for SM/PL and SM/PL-1 N (M) for SM/PLNF and SM/PLNF-1 j. LOAD TYPE: SLIDING 7. Select START CAL and follow the on screen prompt and connect the appropriate calibration standard(s) to complete the calibration. Model SM/PL Series CG PN: 10100-00056 Rev. B...
  • Page 15: Return Loss Verification Procedure

    Use an Ohmmeter to measure the DC resistance between the outer conductor and center conductor of the Precision Load and verify that it is within specification (refer to Table 2-1, “SM/PL Series Specifications). PN: 10100-00056 Rev. B Model SM/PL Series CG...
  • Page 17 Anritsu Company 490 Jarvis Drive Anritsu Prints on Recycled Paper with Vegetable Soybean Oil Ink Morgan Hill, CA 95037-2809 http://www.anritsu.com/...

This manual is also suitable for:

Sm/plSm/plnfSm/pl-1Sm/plnf-1

Table of Contents