12
Care and Maintenance
12
Maintenance intervals
.01
Check the air pressure ......................................................................... daily, before start-up
Clean the air filter of the maintenance unit......................................................... as required
Clean the feed rollers .......................................................................................... as required
Change the lamps ............................................................................................... as required
12
Checking/adjusting the air pressure
.02
1
Fig. 12 - 01
During all cleaning work the machine must be disconnected from the power
supply by switching off the main switch or pulling out the plug!
Danger of injury if the machine is started accidentally!
8
10
6
100
150
12
4
50
200
14
2
230
0
16
0
Care and Maintenance
Before operating the machine, always
●
2
check the air pressure on gauge1.
Gauge 1 must show a pressure of 6 bar.
●
If necessary adjust to this reading.
●
To do so, pull knob 2 upwards and turn
●
it so that the gauge shows a pressure of
6 bar.
63