11. Technical information

11.1 Exchange of a R1000 UDK10 control unit against a R1000 UDK20 control unit

A R1000 UDK10 can be fully replaced by a R1000 UDK20. However, it is necessary that the control unit
has the same suffixes, e.g.: UDK10-B-R by UDK20-B-R .
The terminal blocks are pin compatible. Sensors and cables can be re-used. The previuosly used sensor
PW42GS must be replaced by a sensor PW42AGS.
Controlling the unit via the PLC is identical. The response times of the UDK20 are substantially shorter than
those of the UDK10 (see chapter 2.2 "Sensor data").
It must be ensured that
-
the power supply is capable to supply max. 60W for a UDK20 (max. 17W for UDK10), referred to
chapter 2.5 "Technical data control unit UDK20", and
-
the cross-section of the supply cable is sufficiently dimensioned.

11.2 System configuration

Standard settings are shown in bold letters. Deviations from this standard are to be marked.
Language
D ( )
Sensor type:
PW42AGS ( )
No. of sensors:
1 sensor ( )
Dimension:
mm ( )
Meas. mode:
Demo ( )
66% / 125% ( )
FE-Teach-Limit:
FE Measuring (P):
normal ( )
Password:
yes ( )
Level 0,1,2-sheet:
0V DC ( )
External adjust:
yes ( )
Unit version:
____________
ROLAND ELECTRONIC GMBH · Otto-Maurer-Str. 17 · D-75210 Keltern · Telefon (0049) (07236) 9392-0 · Telefax (0049) (07236) 9392-33
OPERATING INSTRUCTIONS
DOUBLE SHEET DETECTOR R1000 UDK20
E ( )
2 sensors ( )
inch ( )
external single ( )
33% / 142% ( )
fast ( )
no ( )
+24V DC ( )
no ( )
I ( )
F ( )
3 sensors ( )
4 sensors ( )
external continuous ( )
Page 109
SP ( )