7.7 Program parameters

The program parameter contain the necessary information required for the various measurement programs.
Select the mode "configuration program parameter" and confirm with enter.
Program parameter 1: selecting the measuring program.
Here the measuring program (1-255) is selected, for which the parameters are to be adjusted. All of the
following adjustments apply to the selected program number (here: program no. 1).
Program parameter 2: selecting the sensor (1/2 for 2PW, 1-4 for SSB) to be used for measuring.
If the number of sensors was set to "1 sensor" in system parameter 11, then this parameter will not appear.
Possible settings:
2PW unit: 1, 2, 1+2
Unit with SSB: 1, 2, 3, 4
Program parameter 3: adjusting the material of the sheet to be measured.
Possible settings:
Auto: During teach-in the system determines by itself the type of material in front of the sensor.
NF (non-ferrous): Non magnetic material, e.g. aluminium, autenitic stainless steel
FE (ferrous): Magnetic material
mag. NF (LM): low magnetic material
ROLAND ELECTRONIC GMBH · Otto-Maurer-Str. 17 · D-75210 Keltern · Telefon (0049) (07236) 9392-0 · Telefax (0049) (07236) 9392-33
OPERATING INSTRUCTIONS
DOUBLE SHEET DETECTOR R1000 UDK20
Program Par.:
System Param.:12
P12 LW:24-32mS/m
program number:1
Program Par.:
System Param.:12
P12 LW:24-32mS/m
sensor no.:
Program Par.:
System Param.:12
P12 LW:24-32mS/m
material: auto
1
Picture: Selecting the measuring program
2
1
Picture: Selecting the sensor
3
Picture: Adjusting the material
B0048991