Operation; Abbreviated Operating Instructions - Roland udk20 Manual

Double sheet detector
Hide thumbs Also See for udk20:
Table of Contents

Advertisement

ROLAND
Rev. 1.0

8. Operation

8.1 Abbreviated operating instructions

After applying power the type of the system, the version number and the bus system message are briefly
displayed. Afterwards the system switches into that measurement menu, which was active before the unit
was switched off.
Note: The system is factory adjusted for "external single measurement". Therefore
the system functions only if the signal "measurement start" is activated via the PLC
input. The modification of the configuration is described in chapter 7. "Start-up".
LED functions
1-1
FE=1.00
80% <S1=1.02> 120%
Key functions
Functions of the keys (symbols are below the keys)
:
Change the parameters (forward)
:
Change the parameters (backwards)
Enter
:
Selection of a parameter for the change and confirmation of the change
Menü
:
Activation of the menu level, for deleting a fault message and leave the menu level.
Functions of the LEDs (symbols the above the keys)
<
:
ON, if the measured value equals or is below the lower limit value TU or falls below.
Norm
:
ON, if the measured value within the limits TU and TO lies.
>
:
ON, if the measured value reaches or exceeds the upper limit value TO.
Enable
:
- blinks, if a fault occurred
- ON, if the equipment is in the measurement mode
- OFF, during parameter programming with the keyboard
ROLAND ELECTRONIC GMBH · Otto-Maurer-Str. 17 · D-75210 Keltern · Telefon (0049) (07236) 9392-0 · Telefax (0049) (07236) 9392-33
OPERATING INSTRUCTIONS
DOUBLE SHEET DETECTOR R1000 UDK20
-ON
Picture: Frontal view of the R1000 with increased display cutout
1-1
FE=1.00
-ON
80% <S1=1.02> 120%
LED keys
Page 91
Program number
Selected sensor (1-4)
Material
Nominal thickness
Measuring is active
Upper limit value
Measuring value
Sensor no.
Lower limit value