Hitachi wj200 series Quick Reference Manual page 22

Hide thumbs Also See for wj200 series:
Table of Contents

Advertisement

[Setting example]
After power ON, changing from 0.00 display to change the A002 (Run command source)
data.
Press [ESC] key to show
the function code
d001
ESC
Press [ESC] key to move
on to the function group
F001
ESC
Press [ESC] key Once to move
on to the function group A001.
A001
Press Up key to change increase
function code
Press SET key to display the data of
A002
Press up key to increase the
data
(02
When data is changed, the display
starts blinking, which means that new
data has not been activated yet.
SET
:Fixes and stores the data and moves back to the function code
ESC
:Cancels the change and moves back to the function code
Function code dxxx are for monitor and not possible to change.
Function codes Fxxx other than F004 are reflected on the performance just after changing the data
(before pressing SET key), and there will be no blinking.
ESC
SET
F001
A002)
(A001
SET
Display is solid lighting.
ESC
01)
SET
Press SET key to set
and save the data
d001
Data of
will be shown on the
display after the first power ON
0.00
A002
02
01
22

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents