Func.
Name
Code
C028
[AM] terminal selection
(Analog voltage output
0...10V)
C030
Digital current monitor
reference value
C031
Output [11] active state
C032
Output [12] active state
C036
Alarm relay active state
C038
Output mode of low current
detection
C039
Low current detection level
C040
Output mode of overload
warning
C041
Overload warning level
C241
Overload warning level, 2
motor
C042
Frequency arrival setting
for acceleration
C043
Frequency arrival setting
for deceleration
C044
PID deviation level
C045
Frequency arrival setting 2
for acceleration
C046
Frequency arrival setting 2
for deceleration
C047
Pulse train input/output
scale conversion
"C" Function
Description
11 programmable functions:
00...Output frequency
01...Output current
02...Output torque
04...Output voltage
05...Input power
06...Electronic thermal load ratio
07...LAD frequency
10...Heat sink temperature
11...Output torque (with code)
13...General output
16...Option
Current with digital current monitor output
at 1,440Hz
Range is 20%~200% of rated current
Select logic conversion, two option codes:
00...normally open [NO]
01...normally closed [NC]
Two option codes:
00...During acceleration, deceleration and
constant speed
01...During constant speed only
Set the level of low load detection, range
is 0.0 to 2.0 * inverter rated current
Two option codes:
00...During accel., decel. and constant
speed
01...During constant speed only
Sets the overload warning signal level
between 0% and 200% (from 0 to two time
the rated current of the inverter)
nd
Sets the frequency arrival setting
threshold for the output frequency during
acceleration,
range is 0.0 to 400.0(580.0)
Sets the frequency arrival setting
threshold for the output frequency during
deceleration,
range is 0.0 to 400.0(580.0)
Sets the allowable PID loop error
magnitude (absolute value), SP-PV, range
is 0.0 to 100%
Set range is 0.0 to 400.0(580.0)
Set range is 0.0 to 400.0(580.0)
If EO terminal is configured as pulse train
input (C027=15), scale conversion is set in
C047.
Pulse-out = Pulse-in × (C047)
Set range is 0.01 to 99.99
75
A
*1
Hz
*1
Hz
*1
Hz
*1
Hz
Defaults
B
Initial
Units
data
07
[LAD]
Rated
A
current
00
00
01
01
Rated
A
current
01
Rated
current
A
x 1.15
Rated
current
A
x 1.15
0.00
Hz
0.00
Hz
3.0
%
0.00
Hz
0.00
Hz
1.00