Func.
Name
Code
A077
Reverse PID action
A078
PID output limit
a079
PID feed forward
selection
A081
AVR function select
a281
AVR function select,
nd
2
motor
A082
AVR voltage select
a282
AVR voltage select,
nd
2
motor
a083
AVR filter time constant
a084
AVR deceleration gain
A085
Energy-saving
operation mode
A086
Energy-saving mode
tuning
A092
Acceleration time (2)
A292
Acceleration time (2),
nd
2
motor
A093
Deceleration time (2)
A293
Deceleration time (2),
nd
2
motor
A094
Select method to switch
to Acc2/Dec2 profile
A294
Select method to switch
to Acc2/Dec2 profile,
nd
2
motor
"A" Function
Description
Two option codes:
00...PID input = SP-PV
01...PID input = -(SP-PV)
Sets the limit of PID output as
percent of full scale,
range is 0.0 to 100.0%
Selects source of feed
forward gain, option codes:
00...Disabled
01...[O] terminal (voltage in)
02...[OI] terminal (current in)
Automatic (output) voltage
regulation, selects from three
type of AVR functions, three
option codes:
00...AVR enabled
01...AVR disabled
02...AVR enabled except
during deceleration
200V class inverter settings:
......200/215/220/230/240
400V class inverter settings:
......380/400/415/440/460/480
Define the time constant of
the AVR filter, range is 0.000
to 10.00 sec.
Gain adjustment of the
braking performance, range is
50. to 200.%
Two option codes:
00...Normal operation
01...Energy-saving operation
Range is 0.0 to 100.0 %.
Duration of 2
acceleration, range is:
0.00 to 3600 sec.
Duration of 2
deceleration, range is:
0.00 to 3600 sec.
Three options for switching
from 1st to 2nd accel / decel:
00
...2CH input from terminal
01
...Transition frequency
02
...Forward and reverse
A
nd
segment of
nd
segment of
61
Defaults
B
Initial data
00
0.0
00
02
02
230/
400
230/
400
0.300
100.
00
50.0
10.00
10.00
10.00
10.00
00
00
Units
%
V
V
s
%
%
s
s
s
s