6. Adjust the Lens.
1). Connect the VIDEO OUT interface of the camera to the debugging monitor.
2). Set the iris type to MANUAL first.
3). Adjust the No.2 Zoom Lever (T~W) to select a proper angle of view.
4). Adjust the No.1 Focus Lever (F~N) to obtain a perfect image on the monitor.
5). Set the iris type as MANUAL if the environment has a good and stable illumination, and set the
iris type as AUTO if the environment has a strong and changeable illumination.
7. Fit the black liner back to the camera.
8. Align the bubble to camera and fix it by tightening the screws to complete the installation.
Installation Manual of Network Camera
Tilt 0~80°
Rotation 0~350°
Figure 3-99 3-axis Adjustment
Figure 3-100 Adjust the Focus and Zoom
Pan 0~350°
1
2
73