National Instruments RMX-4120 User Manual page 66

Rmx programmable power supplies
Hide thumbs Also See for RMX-4120:
Table of Contents

Advertisement

Parameter Number
CF32
CF33
CF34 to CF36 MAC Address Display
These parameters display the set MAC address. The MAC address is just displayed; it cannot be
set from the panel. To set a fixed MAC address, access the RMX programmable power supply
through a Web browser. When you access the RMX programmable power supply through a Web
browser, do so under conditions in which a DHCP server or AUTO IP can be used. By default,
the MAC address is set to
0 and F).
Parameter
Number
Display
CF34
00.80
CF35
2F.11
CF36
xx.xx
CF40 Resetting (LCI/DEF) or applying (APPL) the LAN Interface Settings
Sets whether to reset or apply the LAN interface settings. This parameter is displayed and can
be set only when the LAN interface is in use.
Value
LCI
dEF
APPL
CF41 IP Address Assignment Method
Sets the IP address assignment method. This parameter is displayed and can be set only when
the LAN interface is in use.
Set whether to use (on: 1) or not use (off: 0) the following: DHCP server, AUTO IP function
(automatic assignment), and MANUAL IP assignment.
If an IP address is not assigned through a DHCP server, AUTO IP is used.
To use the MANUAL IP function, set the DHCP server and AUTO IP function to off. The
address that is assigned by the AUTO IP function is
between 0 and 254).
Display
0 to 255
0 to 255
00.80.2F.11.xx.xx
Displays the first and second MAC address numbers (read only).
Displays the third and fourth MAC address numbers (read only).
Displays the fifth and sixth MAC address numbers (read only).
The LAN interface settings will be reset to their factory default settings.
Resets the LAN interface and network settings (factory default values).
Applies the CONFIG settings related to the LAN interface.
RMX Programmable Power Supplies User Manual
Displays the third IP address number
Displays the fourth IP address number
(where x is a hexadecimal number between
Description
Parameter Description
169.254.x.x
Description
(where x is a number
© National Instruments | 2-35

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents