Figure 26. Fan cage removal
Step 8.
Grasp the fan cage assembly and lift it out of the server.

Installing a simple-swap fan

Use this information to install a simple-swap fan in the server.
The server comes with two 120 mm x 38 mm simple-swap fans in the fan cage assembly. The following
instructions can be used to install any simple-swap fan in the server.
Notes:
1. When you install the second microprocessor, you must also install fan 2 and the air baffle that come
with the second microprocessor upgrade kit. The fan filler can only be removed when fan 2 is installed.
Otherwise, the fan filler must be installed for proper cooling.
44
System x3500 M4 Installation and Service Guide
Thumbscrew
2