Lenovo System x3500 M4 Installation And Service Manual page 558

Table of Contents

Advertisement

Severity
Warning
Serviceable
Yes
Automatically notify support
Yes
Alert Category
System - Predicted Failure
SNMP Trap ID
27
CIM Information
Prefix: PLAT ID: 0168
User Response
1. Run the hard disk drive diagnostic test on drive n.
2. Reseat the following components: a. Hard disk drive b. Cable from the system board to the
backplane.
3. Replace the following components one at a time, in the order shown, restarting the server
each time: a. Hard disk drive. b. Cable from the system board to the backplane. c. Hard disk
drive backplane. (n = hard disk drive number)
806f0223-2101ffff : Powering off system [ComputerSystemElementName] initiated by
[WatchdogElementName]. (IPMI Watchdog)
This message is for the use case when an implementation has detected a Poweroff by Watchdog has
occurred.
May also be shown as 806f02232101ffff or 0x806f02232101ffff
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0372
User Response
No action; information only.