Using The Integrated Management Module Ii (Imm2) - Lenovo System x3500 M4 Installation And Service Manual

Table of Contents

Advertisement

Note: Approximately 20 seconds after the server is connected to AC power, the power-control
button becomes active.
When the prompt <F1> Setup is displayed, press F1. If you have set an administrator password, you
Step 2.
must type the administrator password to access the full Setup utility menu. If you do not type the
administrator password, a limited Setup utility menu is available.
Step 3.
Select System Settings ➙ Integrated Management Module, then set Power Restore Policy
setting to Restore.
Go back to System Configuration and Boot Management ➙ Save Settings.
Step 4.
Go back and check the Power Policy setting to verify that it is set to Restore (the default).
Step 5.
Attention: If you set an administrator password and then forget it, there is no way to change, override,
or remove it. You must replace the system board.

Using the Integrated Management Module II (IMM2)

The Integrated Management Module II (IMM2) is a second generation of the functions that were formerly
provided by the baseboard management controller hardware. It combines service processor functions, video
controller, and remote presence function in a single chip.
The IMM2 supports the following basic systems-management features:
• Active Energy Manager.
• Alerts (in-band and out-of-band alerting, PET traps - IPMI style, SNMP, e-mail).
• Auto Boot Failure Recovery (ABR).
• Automatic microprocessor disable on failure and restart in a two-microprocessor configuration when one
microprocessor signals an internal error. When one of the microprocessors fail, the server will disable the
failing microprocessor and restart with the other microprocessor.
• Automatic Server Restart (ASR) when POST is not complete or the operating system hangs and the
operating system watchdog timer times-out. The IMM2 might be configured to watch for the operating
system watchdog timer and reboot the system after a timeout, if the ASR feature is enabled. Otherwise,
the IMM2 allows the administrator to generate a nonmaskable interrupt (NMI) by pressing an NMI button
on the light path diagnostics panel for an operating-system memory dump. ASR is supported by IPMI.
• A virtual media key, which enables remote presence support (remote video, remote keyboard/mouse,
and remote storage).
• Boot sequence manipulation.
• Command-line interface.
• Configuration save and restore.
• DIMM error assistance. The Unified Extensible Firmware Interface (UEFI) disables a failing DIMM that
is detected during POST, and the IMM2 lights the associated system error LED and the failing DIMM
error LED.
• Environmental monitor with fan speed control for temperature, voltages, fan failure, power supply failure,
and power backplane failure.
• Intelligent Platform Management Interface (IPMI) Specification V2.0 and Intelligent Platform Management
Bus (IPMB) support.
• Invalid system configuration (CONFIG) LED support.
• Light path diagnostics LEDs indicators to report errors that occur with fans, power supplies,
microprocessor, hard disk drives, and system errors.
• Local firmware code flash update
• Nonmaskable interrupt (NMI) detection and reporting.
114
System x3500 M4 Installation and Service Guide

Advertisement

Table of Contents
loading

Table of Contents