Put the end "G" of the
A26/i/i3
finger A 26/1/13 in
contact with the gauge No.
10-2 and put the rear end
"L" of the finger in contact
with the pin "H". The left
branch of the fork "M"
must then be in slight
contact with the pin "N".
Fig. 84
Lever No. D (A
26/3/25) into
working position,
namely, move it
completely to the
right, so that it is
very close to the
arm of the machine
(see Fig. 85).
Loosen slightly the
screw No. 025040
FDB (see Fig. 85) which
holds the small plate No. D (A 26/1/24), as shown in Fig. 85.
With one hand press the stud " D " (Fig. 83), which is firmly
inserted in the small plate No. D (A 26/1/24) as indicated in Fig.
85, slightly against the contact finger No. A 26/1/23, so that the
point of the curved portion of this finger is touching the gauge
No 10-2 while the other hand (working in the opposite way) pres-
ses the head of the screw No. 025040 FDB until a positive resist-
ance is obtained.