GE AF-650 GP Design And Installation Manual page 123

General purpose drive
Hide thumbs Also See for AF-650 GP:
Table of Contents

Advertisement

Specifications
AF-650 GP
Heavy duty/Light duty*
Typical shaft output at 400 V [kW]
Typical shaft output at 460 V [hp]
Typical shaft output at 500 V [kW]
IP21/NEMA 1 Drive Type
IP54/NEMA 12 drive type
IP00 Open Chassis Drive Type
Output current
Continuous (at 400 V) [A]
Intermittent (60 s overload)
(at 400 V) [A]
Continuous (at 460/500 V) [A]
Intermittent (60 s overload)
(at 460/500 V) [A]
Continuous kVA (at 400 V) [kVA]
Continuous kVA (at 460 V) [kVA]
Continuous kVA (at 500 V) [kVA]
Maximum input current
Continuous (at 400 V ) [A]
Continuous (at 460/500 V) [A]
Max. cable size, mains, motor and load
2
share [mm
(AWG)]
Max. cable size, brake [mm
Max. external mains fuses [A]
Estimated power loss at 400 V [W]
Estimated power loss at 460 V [W]
Weight, Unit Size IP21, IP54 [kg/(lb)]
Weight, Unit Size IP00 [kg/(lb)]
5)
Efficiency
Output frequency
Heatsink overtemp. trip [° C/(° F)]
Control card ambient trip [° C/(° F)]
* Heavy Duty=160% torque during 60 s, Light Duty=110% torque during 60 s.
Table 13.8 Technical Specifications, Unit Size 5x 380–500 V
1) American Wire Gauge.
3
13
2) Wiring terminals on N132, N160, and P315 frequency converters cannot receive cables one size larger.
3) For fuse ratings, see chapter 13.3 Fuse Specifications.
4) Typical power loss is at normal conditions and expected to be within
values are based on a typical motor efficiency (IE/IE3 border line). Lower efficiency motors add to the power loss in the frequency converter.
Applies for dimensioning of frequency converter cooling. If the switching frequency is higher than the default setting, the power losses may
increase. Keypad and typical control card power consumptions are included.Options and customer load can add up to 30 W to the losses, though
usually a fully loaded control card and options for slots A and B each add only 4 W.
5) Measured using 5 m (16.4 ft) screened motor cables at rated load and rated frequency.
Efficiency measured at nominal current. For energy efficiency class, see chapter 13.2 General Technical DataEnvironment.
120
HD
315
450
355
600
900
540
810
416
430
468
590
531
4x240 (4x500 mcm)
1)2)
2
1)
2x185 (2x350 mcm)
(AWG)
3)
4) 5)
6794
4)5)
6118
DET-767c All rights reserved.
450 hp
LD
HD
355
355
500
500
400
400
51
51
52
658
658
724
987
590
590
649
885
456
456
470
470
511
511
647
647
580
580
4x240 (4x500 mcm)
2x185 (2x350 mcm)
900
7532
7498
6724
6672
270 (595)
234 (516)
0-590 Hz
110 (230)
85 (185)
±
15% (tolerance relates to variety in voltage and cable conditions.) These
500 hp
LD
HD
400
400
600
550
500
500
51
51
52
745
695
820
1043
678
678
746
1017
516
482
540
540
587
587
733
684
667
667
4x240 (4x500 mcm)
2x185 (2x350 mcm)
900
8677
7976
7819
7814
272 (600)
313 (690)
236 (520)
277 (611)
0.98
550 hp
LD
450
600
530
51
51
52
800
880
730
803
554
582
632
787
718
900
9473
8527
MG35M402