Specifications
AF-650 GP
Heavy duty/Light duty*
Typical shaft output at 400 V [kW]
Typical shaft output at 460 V [hp]
Typical shaft output at 500 V [kW]
IP21/NEMA 1 and IP54/NEMA 12
drive types without/with options
cabinet
Output current
Continuous (at 400 V) [A]
Intermittent (60 s overload)
(at 400 V) [A]
Continuous (at 460/500 V) [A]
Intermittent (60 s overload)
(at 460/500 V) [A]
Continuous kVA (at 400 V) [kVA]
Continuous kVA (at 460 V) [kVA]
Continuous kVA
(at 500 V) [kVA]
Maximum input current
Continuous (at 400 V) [A]
Continuous (at 460/500 V) [A]
2
Max. cable size,motor [mm
(AWG)
Max. cable size,mains 61/62 [mm
1)
(AWG)
]
Max. cable size,mains 63/64 [mm
1)
(AWG)
]
Max. cable size, loadsharing [mm
1)
(AWG)
]
2
Max. cable size, brake [mm
(AWG)
2)
Max. external mains fuses [A]
Estimated power loss
3)4)
at 400 V [W]
Estimated power loss
3) 4)
at 460 V [W]
63/64 maximum added losses A1 RFI,
CB or Disconnect, & contactor 63/64
Maximum panel options losses
Weight, unit size IP21, IP54 [kg]
Weight, rectifier module [kg/(lb)]
Weight, inverter module [kg/(lb)]
4)
Efficiency
Output frequency
Heatsink overtemp. trip [° C/(° F)]
Control card ambient trip [° C/(° F)]
* Heavy duty=160% torque during 60 s, Light duty=110% torque during 60 s.
Table 13.9 Technical Specifications, Unit Size 6x, 380–500 V
1) American Wire Gauge.
2) For fuse ratings, see chapter 13.3 Fuse Specifications.
3) Typical power loss is at normal conditions and expected to be within
values are based on a typical motor efficiency (IE/IE3 border line). Lower efficiency motors add to the power loss in the frequency converter.
Applies for dimensioning of frequency converter cooling. If the switching frequency is higher than the default setting, the power losses may
MG35M402
AF-650 GP™ Design and Installation Guide
600 hp
650 hp
HD
LD
HD
450
500
500
600
650
650
530
560
560
61/ 63
61/ 63
800
880
880
1200
968
1320
730
780
780
1095
858
1170
554
610
610
582
621
621
632
675
675
779
857
857
711
759
759
1)
8x150 (8x300 mcm)
]
2
2
2
1)
4x185 (4x350 mcm)
1600
9031
10162
10146
8212
8876
8860
893
963
951
102 (225)
102 (225)
102 (225)
102 (225)
DET-767c All rights reserved.
750 hp
900 hp
LD
HD
LD
HD
560
560
630
630
750
750
900
900
630
630
710
710
61/ 63
61/ 63
990
990
1120
1120
1089
1485
1232
1680
890
890
1050
1050
979
1335
1155
1575
686
686
776
776
709
709
837
837
771
771
909
909
964
964
1090
1090
867
867
1022
1022
8x240 (8x500 mcm)
8x456 (8x900 mcm)
4x120 (4x250 mcm)
2000
11822 10649 12512 12490 14674 14244 17293 15466 19278
10424
9414
11595 11581 13213 13005 16229 14556 16624
1054
978
1093
1092
400
1017/1318
102 (225)
102 (225)
102 (225)
136 (300)
0.98
0-590 Hz
110 (230)
85 (185)
±
15% (tolerance relates to variety in voltage and cable conditions.) These
1000 hp
1200 hp
LD
HD
LD
HD
710
710
800
800
1000
1000
1200
1200
800
800
1000
1000
62/ 64
62/ 64
1260
1260
1460
1460
1386
1890
1606
2190
1160
1160
1380
1380
1276
1740
1518
2070
873
873
1012
1012
924
924
1100
1100
1005
1005
1195
1195
1227
1227
1422
1422
1129
1129
1344
1344
12x150 (12x300 mcm)
6x185 (6x350 mcm)
2500
1230
2067
2280
2236
1260/1561
136 (300)
136 (300)
102 (225)
102 (225)
LD
1000
1350
1100
1720
1892
1530
1683
1192
1219
1325
1675
1490
2541
13
13
121