Specification
Drain connection number
Drain connection size, in. [mm]
Average flow rate of draining gal/min. [l/
min.]
Average flow rate of draining gal/min. [l/
min.]
Drain pump with hose - internal diameter
of hose, in [mm]
Flow rate of drain pump, gal/min. [l/
min.]
The main drain channel-pipe must have the capacity to be able to
handle the total output of all connected machines. In a drainpipe,
a vent must be provided every 65.62 ft. [20 m] to assure the drain
pipe will work. If the main drain pipe cannot be sufficiently ven-
ted, install a vent per machine. Every time a machine is coupled
1
1. Vent
2. Flow
©
Copyright, Alliance Laundry Systems LLC -
DO NOT COPY or TRANSMIT
Model
35 kg / 80 lb. / 332 L - 52 kg / 115 lb. /
520 L)
All
8 kg / 20 lb. / 80 L - 28 kg / 70 lb. / 280 L
35 kg / 80 lb. / 332 L - 52 kg / 115 lb. /
520 L
8 kg / 20 lb. / 80 L
8 kg / 20 lb. / 80 L
Table 7
A
B
Figure 13
Requirement
2
3 [76]
55.48 [210]
110 [420]
0.75 [19]
9.51 [36]
on the drainpipe, the diameter of the tube or the width of the
waste channel must increase. Refer to Figure 13 .
The diameters of drain pipe for machines with two drain valves
must have dimensions suitable for double the value of water flow.
C
27
Installation
2
CHM2481N_SVG
Part No. D1634ENR4