3. Troubleshooting
Situation
Damaged insulation of the wire
unit of the temperature sensor (ref
D image 3-17) which measures
the temperature at the front of the
DMD of the blue channel. When
disconnecting the wire unit (ref B/FR
image 3-11) of the temperature
sensor from the Formatter Interface
Board (FIB) the error code is
changed to 7685 : "Blue front DMD
temp open".
Defect temperature sensor which
measures the temperature at the
front of the DMD of the blue channel.
Error 7685 : "Blue front DMD temp open"
This error may be preceded by a warning. This error can only appear on the FLM HD series.
Situation
Wire unit (ref B/FR image 3-11)
of the temperature sensor is
disconnected from the Formatter
Interface Board (FIB)
Damaged wire unit of the
temperature sensor which
measures the temperature at
the front of the DMD of the blue
channel.
Defect temperature sensor which
measures the temperature at the
front of the DMD of the blue channel.
Error 7686 : "Blue front DMD temp high"
This error may be preceded by a warning. This error can only appear on the FLM HD series.
Situation
The wire unit of the temperature
sensor at the front of the DMD is
mistakenly switched with one of the
wire units of the other temperature
sensors of the light processor.
The wire units of the TEC's (Peltier
element), mounted on the common
cooling block of the heat pipes, are
mistakenly switched.
No thermal contact between heat
pipes and common cooling block
due to loose screws.
Malfunction TEC between heat
pipes and common cooling block.
Use the "diode test" of a multi-meter
to check out the TEC. Polarity
doesn't matter. The TEC is not
OK in case the measured value is
higher then 0,01 volt.
38
Solution
Repair the insulation of the wire unit using shrink sleeve.
If not repairable, replace the light processor. Contact Barco for further instructions
to repair the malfunction light processor.
Replace the light processor. Contact Barco for further instructions to repair the
malfunction light processor.
Solution
Plug in the wire unit of the temperature sensor into its socket on the Formatter Interface
Board. See image 3-11.
Repair the wire unit.
If not repairable, replace the light processor. Contact Barco for further instructions
to repair the malfunction light processor.
Replace the light processor. Contact Barco for further instructions to repair the
malfunction light processor.
Solution
Check if all wire units of the temperature sensors are plugged into their respective
sockets on the Formatter Interface Board. See image 3-11.
Check if all wire units of the TEC's for front cooling are plugged into their respective
sockets on the Formatter Interface Board. See image 3-11.
Check if the four screws, which attach the heat pipes of the involved channel to the
common cooling block, are fastened. See image 3-18.
Remove the light processor from its compartment and replace the malfunction TEC.
If problem persist contact Barco for further instructions.
R59770072 FLM SERIES 19/03/2007

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Flm r20+Flm hd18Flm hd14

Table of Contents