Error 2005 : "Lamp stop failed"
Situation
No communication with the Lamp
Power Supply.
Error 2006 : "One LPS down, reduced power"
This is not a real error but a warning. The projector will continue to operate.
Situation
Main power cable disconnected
from one of the LPS units
Disconnected wire unit between
the "CTRL IN" and "CTRL OUT"
sockets of the LPS units.
Malfunctioning of one of the LPS
units. The red LED "ERR" of the
malfunctioning LPS unit flashes
fast.
Error 2201 : "PFC start failed"
This error is generated by the LPS unit with address 0x20.
Situation
The power factor corrector of one of
the LPS units fails to start.
Error 2202 : "LPS start failed"
This error is generated by the LPS unit with address 0x20.
Situation
One of the LPS units fails to start.
Error 2203 : "BOOST start failed"
This error is generated by the LPS unit with address 0x20.
Situation
One of the LPS units fails to place
the start up voltage of 140 volt,
which is required to trigger the SPG,
on the "LAMP OUT" pins of the LPS
unit.
Error 2206 : "Lamp ignition failed"
This error is generated by the LPS unit with address 0x20.
R59770072 FLM SERIES 19/03/2007
Solution
Switch off the projector.
Reboot the projector. If problem remains, replace the Lamp Power Supply.
Solution
Check if the main power cable is connected with the "MAINS INPUT" socket of the
LPS unit (image 3-9).
Reconnect the wire unit between the "CTRL IN" and "CTRL OUT" sockets of the LPS
units (image 3-7).
Replace the LPS module.
Solution
Replace the LPS module.
Solution
Replace the LPS module.
Solution
Replace the LPS module.
3. Troubleshooting