16. FLM liquid cooling circuit
Image 16-12
Filling part of cooling liquid circuit, light processor excluded
3. Fill the syringe with cooling liquid as follows:
a) Couple the female (F) fitting of a plastic tube to male (M) fitting of the syringe and emerge the tube end. Make sure that the
piston of the syringe is completely pressed in.
b) Extract cooling liquid into the syringe by pulling out the piston.
c) Turn the syringe upside down, so that the air inside the syringe is located at the outlet.
d) Push the piston in until all air bubbles inside the syringe and tubes are expelled. Ensure that the tube end in the bottle remains
emerged.
e) Pull out the piston to fill the tubes and syringe completely with cooling liquid. Keep holding the syringe upside down.
f) Disconnect the filled syringe from the tube. Make sure that there is no air inside the tube or syringe. If necessary push the
air outside the syringe and tube before disconnecting.