3. Troubleshooting
Error 2001 : "Mains voltage to low"
Situation
The mains voltage applied to the
"MAINS INPUT" sockets of the LPS
module is to low.
Image 3-9
Error 2002 : "Lamp start failed"
The Lamp Power Supply succeeded in igniting the lamp but shortly after ignition the lamp goes out.
Situation
Hot restrike of the lamp. The lamp
fails to illuminate when switched on
shortly after the lamp was switched
off.
Lamp with many strikes, maximum
run time exceeded. The Lamp
Power Supply and the Start Pulse
Generator are working normally.
Nevertheless, the lamp fails to
illuminate.
Malfunction SPG unit. You can not
hear the SPG module three times
clicking in an attempt to ignite the
lamp. The voltage on the "LAMP
OUT" pins of the LPS module is first
140 volt during the attempt to ignite
and then drops to 0 volt after a few
minutes.
Note: The ambient noise must be
low to hear the SPG clicking in an
attempt to ignite the lamp.
Error 2004 : "Lamp goes out"
Situation
Exhausted lamp. Lamp with
many strikes, maximum run time
exceeded.
22
Solution
Check if the main power cables (image 3-9) are connected with the "MAINS
INPUT" sockets of the LPS module.
Check if the mains voltage applied to the projector power socket is between 200
and 240 VAC.
Make sure that the electrical dimensions of the extension leads to the projector
meet the power requirements of the projector.
Solution
Let cool down the lamp for at least 3 minutes before switching the projector from
standby to operating mode.
Replace the exhausted lamp with a new one.
Check the cabling of the SPG module.
Replace the SPG module.
Solution
Replace the exhausted lamp with a new one.