16. FLM liquid cooling circuit
3. Fill a plastic tube, which contains a male fitting, with cooling liquid as follows:
a) Connect a tube, which contains a male (M) fitting, to the male (M) fitting of the syringe using a female/female (F) adapter.
b) Emerge the tube end and make sure that the piston of the syringe is completely pressed in.
c) Extract cooling liquid into the syringe by pulling out the piston.
d) Disconnect the filled tube from the syringe. Make sure that the tube remains immersed.
a
M
F
F
M
Image 16-18
Caution:
It's important that there is no air inside the tube. The pump is not self priming and hence is only capable of sucking
through small volumes of air.
4. Push the male valved fitting of the filled tube into the female valved fitting at the heat exchanger. This is the entrance of the liquid
cooling circuit. Make sure that the inlet of the filled tube remains immersed.
IN
Image 16-19
168
b
c
OUT
d