Barco FLM series Service Manual page 312

Hide thumbs Also See for FLM series:
Table of Contents

Advertisement

28. Start pulse generator
Image 28-8
4. Connect the power cables coming from the SPG module with the "LAMP OUT" sockets of the LPS module as illustrated.
Warning: Make sure to place the washers and cable eyes in correct order upon the pin as illustrated. Always use a plain
washer between the output pin and the cable eyes.
Image 28-9
P
LPS output pin.
W Plain washer.
L
Lock washer.
E1 Cable eye from SPG module.
E2 Cable eye from LPS unit.
N
Nut.
Warning: Respect the polarity of the socket and cables. Red marked cables with the "+" pin, black marked cables with the "-"
pin.
310
P
W
E1
E2
L
R59770072 FLM SERIES 19/03/2007
N