45
dd
46
nn
dd –
command to switch into DAY mode [2 digits]
nn –
command to switch into NIGHT mode [2 digits]
Note. The switchover to Day/Night mode remains set in unit even after line disconnection.
Parameter Value
47
e
e – operating mode of unit
e=0 for 2 Group mode, e=1 for Day/Night mode.
Parameter Value
4*
k
k – line hanging up by push of same button:
k=0 feature is switch off
k=1 again button push hang up the line

5.4. Time parameters

Parameter Value
51
q
q – number of incoming call rings .
Parameter
Value
52
d
D – Maximum time in minutes for which a call may last. This time can be extended
during a call by dialing Prolong Call digit from telephone (∗ or #). Time setting is per
table.
Linkcom France
11 rue du Soleil Levant 92140 CLAMART
Day mode switching
(00-99,*0-*9)
Night mode switching
(00-99,*0-*9)
Description
Dialing mode (0/1)
Description
End call by push again the same button
(0/1)
Description
Number of rings before picks up (1-9)
Description
Maximal call duration (0-9,*,#)
11
10
Default
1
Default
1
Default
2
Default
2
Copyright © 2011 – Linkcom – All rights reserved
time[min]
Dial
0,5
0
1 -
1 - 9
9
15
*
30
#