Technical Parameters; Electrical Parameters; Mechanical Dimensions - Linkcom link smile User Manual

Table of Contents

Advertisement

87
80
9

6. Technical parameters

6.1. Electrical parameters

Parameter
Minimal line current
Minimal line voltage
Line voltage during OFF
HOOK (VA characteristic)
Downlead during ON HOOK
Line termination impedance
Bandwidth
Ringing impedance
Sensitivity of ringing
detector
Pulse dial
Tone dial level
Sensitivity of tone dial
Sensitivity of tones detector
Powering of backlight, relays
and heating
Max consumption of
backlight and heating
Max voltage of relay contact
Max current of relay contact
Operation temperature
IP rate
Weight

6.2. Mechanical dimensions

Model
Brave Slim
Screw 2x
Wall plug 2x
Linkcom France
11 rue du Soleil Levant 92140 CLAMART
Default setting for Parameters 7x only
Default setting for Parameters 0x only
END
Value
18mA
18V
< 8V
< 12V
< 30uA
220R +
820R
paral. 115nF
300Hz – 3400 Hz
> 2Kohm
min. 10 – 25 V
40 / 60 ms
-6 and -8 dB
min. -40 dB
min. -30 dB
12Vss ± 2V , 10-12Vst ± 2V
250mA
48V
1,5A
-20 to +60°
IP44
max. 350g
dimension HxWxD [mm]
185 x 99 x 40
Screw 3.5x30 half round head
UPA,UPP pr. 5 x 25
Conditions
Line OFF HOOK
Line ON HOOK
I = 20mA
I = 60 mA
U = 60V
Line OFF HOOK
20 - 60mA
25 – 60 Hz
20 – 60 mA
20 – 60 mA
20 – 60 mA
12Vss
when I < 1A
when U < 30 V
Copyright © 2011 – Linkcom – All rights reserved
21

Advertisement

Table of Contents
loading

Table of Contents