Check Cell IP Address

> show interfaces-state interface Cell ipv4
ipv4 forwarding true
ipv4 mtu 1500
IP
-------------------------------------------------------------------------------------------------------------
166.130.200.173
IP
---------------------------------------------------------------------------------------------------------------
0.0.0.0
Determining the Cell Module's IMSI/IMEI
When provisioning the cell module for network service, the cellular provider typically requires the
International Mobile Subscriber Identity code (IMSI) or International Mobile Station Equipment Identity
code (IMEI) to be provided. These codes can be determined by entering the following command:
> show interfaces-state interface Cell cell-status
where Cell is the configured name for the cellular device. Cell is the factory default name, but it may have
been changed by a previous user.
When the previous command is entered, a number of items are returned as shown in the example below.
The first two items (highlighted blue) show the IMSI and IMEI codes. These are unique for each unit.
cell-status imsi 311480023631413
cell-status imei 990000947608727
cell-status iccid 89148000000232694605
cell-status mdn 5857948168
cell-status apn VZWINTERNET
cell-status app-sw-version 0.0.5
cell-status modem-sw-version "4.08.02 SVN 0 [2012-12-21 10:52:58]"
cell-status sim-state Ready
cell-status modem-state connected
cell-status roaming-state home
cell-status service-state lte
cell-status rssi -62

3.5.2.2 Cell Modem Reprogramming

Understanding
The cell modem has its own set of firmware supplied by the wireless carrier. Occasionally new versions
of this firmware become available. The user has the option to upgrade the cell modem firmware if they
wish to do so.
GE posts new cell firmware at:
http://www.gegridsolutions.com/communications/mds/software.asp?directory=Orbit_MCR/Cell