The menu that appears lists all rules contained within the new rule set. Since this is a new rule set, there
are currently none. Click the Add button to add a rule. The Configure Rule Details menu appears.
Enter a numeric ID for the rule and click the Add button. It is important to remember that rules are
applied in ascending order. This means that a rule with ID 2, for example, would be processed after a rule
of ID 1. Therefore, if the rules in a rule set should be applied in a particular order, care must be taken to
set the IDs accordingly. In this example, only one rule is required.
Clicking the Add button leads to additional items to configure for new rule.
The following main sections can be accessed from this screen:
Match – Edit this section if the rule should be applied to a particular source or destination address.
Source NAT – Edit this section if the rule should be applied to a specific interface or address.
Since the rule in this example applies to the cellular interface, configuration will be done on the Source
NAT section.
232
Figure 3-148. Add New Rule menu
Figure 3-149. Rule menu