For example, consider the case shown in the figure below. An Orbit MCR, located at a remote site,
maintains a connection to the backhaul network on its ETH1 connection, and also serves as a WiFi access
point. The contract technicians who visit the remote site need to be able to use the WiFi connection so
that they can access the corporate intranet through the MCR, but the system administrators have
determined that they should not be able to manage the MCR or change its configuration. Therefore,
device management is allowed solely on ETH1's IP address.
A contractor's laptop should be able to access the corporate intranet through the WiFi connection, while
remaining unable to manage the MCR.
Configuration
Web UI - HTTP/HTTPS Configure
To limit services to a specific statically assigned IP address, navigate to Web Server ---> Basic Config
menu.
HTTP
Enabled - Enable (Default) or Disabled Service.
Port - The port to listen to HTTP connections on Valid values: 0—65535 -Default: 80
IPv4 Bind IPs - Restrict the server to only listen for connections on the specified IPv4 addresses. If
not present, or empty, the server will listen on all IPv4 addresses.
MDS 05-6632A01, Rev. F
Figure 3-194. Device Management Example Network.