Cisco Ip Phone 7800 Series Administration Guide For Cisco Unified Communications Manager - Cisco 7800 series Administrator's Manual

Hide thumbs Also See for 7800 series:
Table of Contents

Advertisement

Field Name
Field Type
or Choices
Enable Audible Alert
Checkbox
EnergyWise Domain
Up to 127 characters
EnergyWise Secret
Up to 127 characters
Allow EnergyWise
Check box
Overrides
Default
Description and Usage Guidelines
Unchecked
When enabled, instructs the phone to play an audible alert
starting 10 minutes before the time that the Phone Off Time
field specifies.
This check box applies only if the Enable Power Save Plus list
box has one or more days selected.
Identifies the EnergyWise domain that the phone is in.
Identifies the security secret password that is used to
communicate with the endpoints in the EnergyWise domain.
Unchecked
Determines whether you allow the EnergyWise domain
controller policy to send power level updates to the phones.
The following conditions apply:
For example, assuming the Phone Off Time is set to 22:00
(10:00 p.m.), the value in the Phone On Time field is 06:00
(6:00 a.m.), and the Enable Power Save Plus has one or more
days selected.
To disable Power Save Plus, you must uncheck the Allow
EnergyWise Overrides check box. If the Allow EnergyWise
Overrides remains checked but no days are selected in the
Enable Power Save Plus field, Power Save Plus is not disabled.

Cisco IP Phone 7800 Series Administration Guide for Cisco Unified Communications Manager

Phone Feature Configuration
• One or more days must be selected in the Enable Power
Save Plus field.
• The settings in Cisco Unified Communications Manager
Administration take effect on schedule even if
EnergyWise sends an override.
• If EnergyWise directs the phone to turn off at 20:00 (8:00
p.m.), that directive remains in effect (assuming no phone
user intervention occurs) until the configured Phone On
Time at 6:00 a.m.
• At 6:00 a.m., the phone turns on and resumes receiving
the power level changes from the settings in Cisco
Unified Communications Manager Administration.
• To change the power level on the phone again,
EnergyWise must reissue a new power level change
command.