Electrolux W365H Service Manual page 49

Hide thumbs Also See for W365H:
Table of Contents

Advertisement

Service
Manual
19E
Communication between CALCAD 4400 and
the programme unit card A1 has been
interrupted.
If the power is on, be very careful when
working on the machine.
Try to restart the machine (i.e. reset the error
code) by pressing the Start button quickly.
If the error returns, troubleshoot as follows:
1. Is the machine connected to CALCAD 4400?
Yes
2. Enter the service programme (code 96). Short-
Fig.
circuit card switches X70:3 - 4 on the
27
communication card A21 and read the displayed
value.
0 is displayed
Replace the programme
unit card A1.
3. Verify that CALCAD operates and that the network
cabling has been correctly connected to the
communication card.
OK
4. Inspect the RS232 interface cabling between the
programme unit card and the CALCAD equipment.
Measure the resistance (
and verify that the connection is OK. Also measure the
connections to be sure there is no short-circuit between
any two leads.
Cabling OK
Troubleshoot CALCAD according to
the instructions in the CALCAD
manual.
438 9152-31/06
05.03
12. Troubleshooting
No
1 is displayed
Press the On/Off button
while the short-circuit
above is maintained so
that 0 is displayed. Exit
the service programme
and remove the short-
circuit. Start the
machine.
Not OK
Troubleshoot CALCAD according to the
instructions in the CALCAD manual.
) of the four coloured leads
Cabling defective
Inspect the cabling
and replace if
necessary.
27
Service programme switch
X70:3 - 4
12
5182
23