Service
Manual
02E
No signal from the "Door closed" switch
during programme operation.
If the input signal for "Door closed" is lost
during programme operation, error code 02 is
immediately generated.
If the power is on, be very careful when
working on the machine.
1. Try to restart the machine (i.e. reset the error code)
by pressing the Start button quickly.
Error message returns
2. Exit the programme using the Start button. Enter the
Fig.
service programme (if the door is locked, unlock it
11
using service code 23). Verify that voltage supply is
Fig.
present between X30:1 - 4 when the door is closed.
12
No voltage
3. Verify that voltage supply is present between
X30:1 - 3.
Voltage present
Continued on next page
438 9152-31/06
05.03
12. Troubleshooting
No error message
Temporary error (probably
defective contact)
Voltage present but LED
does not light
The programme unit card
A1 is probably defective.
No voltage
Troubleshoot the cabling for
the voltage supply (between
the main power switch Q1
and X33).
11
X33
X30
Alt.
12
Indication Door locked
95
60
40
60
40
12
5418
X30
X33
5566 D
20
5392
11