Error code
Cause
01E
Water level ACK not received within the prescribed time.
02E
No signal from the "Door closed" switch during programme operation.
03E
No signal from the "Door locked" switch at programme start or during
programme operation.
04E
The temperature sensor indicates a temperature below -5°C or
interruption in sensor.
05E
The temperature sensor indicates a temperature above 98°C or short-
circuit in sensor.
06E
The water level is too high at programme start (above the safety level).
07E
The water level is too high during programme operation (above the
measurable level).
08E
The water temperature rises too slow.
10E
The water level is above the safety level after the drain sequence.
11E
Mechanical unbalance always activated.
12E
The programme unit cannot read the programme memory (EPROM).
13E
The programme unit cannot communicate with the motor controller.
14E
The water level system has not been calibrated (hardware calibration).
17E
The signal from the "Door locked" switch is present although there is
no signal from the "Door closed" switch.
18E
CALCAD 4400 doesn´t allow start of selected program.
19E
Communication between CALCAD 4400 and the programme unit card
has been interrupted.
21E
Microprocessor error (Configuration register).
22E
The level system indicates such a wrong value at program start that the
automatic level calibration cannot correct the fault.
31E
The motor controller indicates the temperature is too high on the motor
controller heat dissipator.
32E
The motor controller indicates the thermal protector of the motor has
triggered.
33E
The motor controller receives a start command from the programme
unit without receiving an interlock ACK ("Door locked" signal).
35E
The motor controller indicates a short-circuit in the motor windings,
cabling or internally in the motor controller.
36E
The motor controller indicates an error in the interlock receiving circuit.
37E
The motor controller indicates the DC voltage
38E
The motor controller indicates the DC voltage level is too high.
41E
The motor controller indicates an error in the thermal protection circuits
of the motor.
45 E
Indicates tacho pulses missing at requested revolutions/motor does not
rotate.
438 9152-31/06