Manual
X304: Opto output
Fig.
17
The.opto.function.is.controlled.from.the.pro-
gramme.unit.(X301)..The.output.does.not.switch.
on.if.there.is.no.communication.with.the.pro-
gramme.unit..Tacho.signal.from.the.motor.(via.
door.lock.control.A31).is.needed.to.control.the.
motor.
Card.No.. .
X304:1.
.
X304:2.
.
X304:3.
.
Voltage,.max:.
Current,.max:.
X308: Imbalance switch
Input.from.the.imbalance.switch.(only.fitted.on.
some.machines)..The.imbalance.switch.is.usu-
ally.open.
.Input.voltage.
. .
min:.
. .
max:.
Current:. max:.
X311: Voltage supply
Input.voltage,.single.phase.or.rectified.three-phase.
. .
min:.
. .
max:.
438 9150-21/06
06.42
30. Motor and motor control
Connection
Emitter-opto,.0V
Tacho.signal
Collector-opto
30V.DC
.
.10.mA
120.V-20.%..
50/60.Hz.
240.V+15.%.
50/60.Hz
.0,01.A
200V-15%
240V+10%
17
FLASH
EPROM
30
X311
5930
17