Electrolux W365H Service Manual page 109

Hide thumbs Also See for W365H:
Table of Contents

Advertisement

Service
Manual
X95: Input from rotation sensor on motor
Fig.
shaft
10
When the motor is operating, a pulse train is
Fig.
applied on the input.
11
Input
Function
Pin 1:
DC 4-10 V feed
Pin 2:
0V
Pin 3:
DC 4-10 V pulse input
Frequency > 0.4 Hz: drum is rotating
Frequency < 0.4 Hz: drum is not rotating
X96: Output to door lock
Locks the door lock when the following conditions
are met:
• DC 200-240 V on input X92 (programme unit
requests door locking).
• DC 0 V on input X93 (no water in drum).
• DC +5 V on input X94 (motor not operating).
• <0.4 Hz on input X95 (drum not rotating).
• No error code present.
Unlocks the door lock when the following
conditions are met:
• DC 0 V on input X92 (programme unit
requests door unlocking).
• DC 0 V on input X93 (no water in drum).
• DC +5 V on input X94 (motor not activated).
• <0.4 Hz on input X95 (drum not rotating).
• No error code present.
Voltage
17 - 31 V DC, + on pin 1, - on pin 2
17 - 31 V DC - on pin 1, + on pin 2
438 9150-01/06
04.10
29. Door and door lock
Function
Unlocks the door
Locks the door
10
Door lock control A31
Rotation sensor
B3
X95
1
2
3
Unlocks +
Locks
Y80
Door lock A41
11
29
-
-
+
1
2
X96
5194
5184