Remote Register Assignment - Toshiba TOSVERT VF-AS1 Function Manual

Hide thumbs Also See for TOSVERT VF-AS1:
Table of Contents

Advertisement

4.4.2.

Remote Register Assignment

Divide the monitor code (RWw n) into half and select the first monitor description (RWr n)
from the lower 8 bits and the second monitor description (RWr n) from the higher 8 bits.
(Example) When output voltage is selected for the first monitor and output torque is
selected for the second monitor. -> The monitor code is 0703H.
* The hexadecimal value attaches and expresses "H" to the end of a number.
(1) Remote register
(Master -> inverter)
RWw signal
Address
Signal name
RWw n
Monitor code
Set frequency
RWw (n+1)
Set torque
Command
RWw (n+2)
code
RWw (n+3)
Write data
"n" is depend on the station number.
Remote
Address
register
1E0H
RWw0
No.1
1E1H
RWw1
1E2H
RWw2
1E3H
RWw3
1E4H
RWw4
1E5H
RWw5
No.2
1E6H
RWw6
1E7H
RWw7
Sets the monitor code to be referenced. By switching on the (RYnC) signal after
setting, the specified monitored data is set to (RWrn).
The first monitor (RWr n) : RWw n Setting of the lower 8 bits of monitor code.
The second monitor (RWr n+1) : RWw n Setting of the higher 8 bits of monitor
Specifies the set frequency. After setting the register, a frequency is written after
turning on the RYnD. When the writing of the frequency is completed, RXnD turns
on, depending on the input command.
Specifies the set torque. After setting the register, a torque is written after turning
on the RYnE. When the writing of the torque is completed, RXnE turns on,
depending on the input command.
Sets the command code for actions such as operation mode switching, parameter
read, write, error reference, error clear, etc. The command will be executed by
turning RYnF on after the register setting is completed. When the command
execution is completed, RXnF turns on.
Sets data specified by the above-mentioned command code (if necessary).
If no data needs to be written, the value shall be zero.
RYnF is turned on after setting the above-mentioned command code and this
register.
Remote
Address
register
1E8H
RWw8
No.3
1E9H
RWw9
1EAH
RWwA
1EBH
RWwB
1ECH
RWwC
RWwD
No.4
1EDH
RWwE
1EEH
RWwF
1EFH
− 
Description
code.
Remote
Address
register
RWw10
1F0H
RWw11
No.5
1F1H
RWw12
1F2H
RWw13
1F3H
RWw14
1F4H
RWw15
No.6
1F5H
RWw16
1F6H
RWw17
1F7H
13  −
E6581288①
Remote
Address
register
RWwFC
2DCH
RWwFD
No.64
2DDH
RWwFE
2DEH
RWwFF
2DFH

Hide quick links: