4.4.4.

The details of an error code

The following data are stored as trip history data when the inverter trip occurred.
Decimal
No.
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
29
30
32
33
34
36
(It continues to the next.)
Error code
Hexadecimal
No.
00H
No error
01H
Overcurrent during acceleration
02H
Overcurrent during deceleration
03H
Overcurrent during fixed speed operation
04H
Dynamic braking element overcurrent
05H
U-phase arm overcurrent
06H
V-phase arm overcurrent
07H
W-phase arm overcurrent
08H
Input phase failure
09H
Output phase failure
0AH
Overvoltage during acceleration
0BH
Overvoltage during deceleration
0CH
Overvoltage during fixed speed operation
0DH
Inverter overload
0EH
Motor overload
0FH
Dynamic braking resister overload
10H
Overheating
11H
Emergency stop
12H
EEPROM fault (writing error)
13H
Initial read error (parameter initialization)
14H
Initial read error (parameter initialization)
15H
Inverter RAM fault
16H
Inverter ROM fault
17H
CPU fault
18H
Communication error interruption
19H
Gate array fault
1AH
Output current detector error
1BH
Communication error (f851 set to 4.)
1DH
Low current operation
1EH
Undervoltage (main circuit power supply)
20H
Overtorque
21H
Ground fault
22H
Dynamic braking abnormal element
24H
(200V-55kW or larger, 400V-90kW or larger)
Description
16  −
− 
E6581288①